29 / 108 page ![]() 15 14 13 12 11 10 9 8 CLKOUT Disable OSC Disable HIDL BKE SR STAT HOLD HOLDA CKE SEL R/W, 0 R/W, 0 R/W, 0 R/W, 0 R/W, 0 R/W, 0 R/W, 1 R/W, 0 7 6 5 2 1 0 CKE EN SR CMD Reserved (see NOTE) Parallel Port Mode R/W, 0 R/W, 0 R, 0000 R/W, 01 if GPIO0 = 1 11 if GPIO0 = 0 LEGEND: R = Read, W = Write, n = value after reset NOTE: These bits are Reserved and must be kept as 0000 during any writes to EBSR. SM320VC5507-EP www.ti.com SPRS613 – SEPTEMBER 2009 3.6.1 External Bus Selection Register (EBSR) The External Bus Selection Register determines the mapping of the 21 address signals, 16 data signals, and 15 control signals of the external parallel port. The External Bus Selection Register is memory-mapped at port address 0x6C00. Once the bit fields of this register are changed, the routing of the signals takes place on the next CPU clock cycle. The reset value of the parallel port mode bit field is determined by the state of the GPIO0 pin at reset. If GPIO0 is high at reset, the full EMIF mode is enabled and the parallel port mode bit field is set to 01. If GPIO0 is low at reset, the HPI multiplexed mode is enabled and the parallel port mode bit field is set to 11. After reset, the parallel port should be selected to function in either EMIF mode or HPI mode. Dynamic switching of the parallel port, once configured, is not recommended. Figure 3-4. External Bus Selection Register Table 3-5. External Bus Selection Register Bit Field Description BITS DESCRIPTION CLKOUT disable 15 CLKOUT disable = 0: CLKOUT enabled CLKOUT disable = 1: CLKOUT disabled Oscillator disable. Works with IDLE instruction to put the clock generation domain into IDLE mode. 14 OSC disable = 0: Oscillator enabled OSC disable = 1: Oscillator disabled Host mode idle bit (applicable only if the parallel bus is configured as EHPI) x When the parallel bus is set to EHPI mode, the clock domain is not allowed to go to idle, so a host processor can access the DSP internal memory. The HIDL bit works around this restriction and allows the DSP to idle the clock domain and the EHPI. When the clock domain is in idle, a host processor will not be able to access the DSP memory. 13 HIDL = 0: Host access to DSP enabled. Idling EHPI and clock domain is not allowed. HIDL = 1: Idles the HPI and the clock domain upon execution of the IDLE instruction when the parallel port mode is set to 10 or 11 selecting HPI mode. In addition, bit 4 of the Idle Control Register must be set to 1 prior to the execution of the IDLE instruction. Bus keeper enable(1) 12 BKE = 0: Bus keeper, pullups/pulldowns enabled BKE = 1: Bus keeper, pullups/pulldowns disabled SDRAM self-refresh status bit 11 SR STAT = 0: SDRAM self-refresh signal is not asserted. SR STAT = 1: SDRAM self-refresh signal is asserted. (1) Function available when the port or pins configured as input. Copyright © 2009, Texas Instruments Incorporated Functional Overview 29 Submit Documentation Feedback Product Folder Link(s): SM320VC5507-EP |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |