| поискавой системы для электроныых деталей |
|
VSC8504-02 датащи(PDF) 46 Page - Microsemi Corporation |
|
|
|||||||||||||||||||||||||||||
VSC8504-02 датащи(HTML) 46 Page - Microsemi Corporation |
|
46 / 131 page ![]() Functional Descriptions VMDS-10507 VSC8504-02 Datasheet Revision 4.2 35 3.17.6.2 QSGMII Mode When the MAC interface is configured in QSGMII mode, write the following 16-bit value to register 18G: Bits 15:12 0x9 Bits 11:8: Port address (0x0) Bits 7:4: Loopback type Bits 3:0: 0x2 where loopback type is: 0x0: No loopback 0x2: Input loopback 0x4: Facility loopback 0x8: Equipment loopback Note: Loopback configuration affects all ports associated with a QSGMII. Individual port loopback within a QSGMII is not possible. 3.17.6.3 Fiber Media Port Mode When the SerDes is configured as a fiber media port, write the following 16-bit value to register 18G: Bits 15:12: 0x8 Bits 11:8: Port address Bits 7:4: Loopback type Bits 3:0: 0x2 where port address is: 0x1: Fiber0 port 0x2: Fiber1 port 0x4: Fiber2 port 0x8: Fiber3 port Port addresses for fiber media SerDes can be OR'ed together to address multiple ports using a single command. bit 18G.15 will be cleared when the internal configuration is complete. 3.17.6.4 Facility Loop The recovered and de-multiplexer deserializer data output is looped back to the serializer data input and replaces the data delivered by the digital core. This test loop provides the possibility to test the complete analog macro data path from outside including input buffer, clock and data recovery, serialization and output buffer. The data received by the input buffer must be transmitted by the output buffer after some delay. Additional configuration of the macro is required for facility loopback mode. When entering facility loopback mode, the set = 1 option should be run; when exiting facility loopback mode, the set = 0 option should be run. PhyWrite(PhyBaseAddr, 31, 0x0010); PhyWrite(PhyBaseAddr, 18, 0x8s03); // where “s” is the physical address of the SerDes macro PhyWrite(PhyBaseAddr, 18, 0xd7cb); PhyWrite(PhyBaseAddr, 18, 0x8007); tmp1 = PhyRead(PhyBaseAddr, 18); tmp2 = tmp1 & 0x0ff0; if (set) tmp3 = tmp2 | 0x0010; |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |