22 / 84 page ![]() ADP1053 Data Sheet Rev. A | Page 22 of 84 The unregulated Channel C can be programmed to be always on, or it can be programmed to be on when either PSON_A or PSON_B is on. This option is configured using Bit 4 of Register 0xFE7B. Software Reset The user can reset the ADP1053 power supply by writing the GO command to Register 0xFE88 (Bit 0 for Channel A; Bit 1 for Channel B). When the GO bit is written, the power supply for Channel A or Channel B is immediately turned off, and the channel is restarted with a soft start after a preset delay. The delay can be programmed to 0 ms, 500 ms, 1 sec, or 2 sec using Bits[3:2] of Register 0xFE88. PSON Sequencing For both the regulated Channel A and Channel B and the unregulated Channel C, the turn-on delay, turn-off delay, and ramp rate can be independently configured. The register settings can be used to set up the sequencing of the channels. Figure 21 shows a typical sequencing diagram. • The turn-on delays (tDON_A, tDON_B, and tDON_C) are the delay times between the activation of the PSON_A/PSON_B pins or commands that trigger the turn-on signal and the start of the output ramp-up. • The turn-off delays (tDOFF_A, tDOFF_B, tDOFF_C) are the delay times between the activation of the PSON_A/PSON_B pins or commands that trigger the turn-off signal and the start of the output shutdown. The turn-on and turn-off delays for Channel A, Channel B, and Channel C can be set to 0 ms, 50 ms, 250 ms, or 1 sec using Register 0xFE79, Register 0xFE7A, and Register 0xFE7B, respectively. tDON_A tDOFF_C tDON_B tDON_C PSON_A/ PSON_B VOUTA VOUTB VOUTC tSS_A tSS_B tSS_C tDOFF_A tDOFF_B Figure 21. PSON Sequencing Diagram The PGOOD signal of a master controller can be configured to trigger the PSON signals of multiple slave controllers. The ADP1053 also has fault link functionality; that is, the part can be configured to shut down an output after another output is shut down. Soft Start Ramp For either regulated channel of the ADP1053, the VS_A/VS_B reference voltage increases from 0 V to the regulated reference voltage after the PSON signal is received and after the turn-on delay. The ramp rate for the reference voltage is set in Register 0xFE2A for Channel A and Register 0xFE2B for Channel B. The first column of Table 8 shows the possible ramp rates for the VS_A and VS_B references. A non-zero prebias may result in a longer turn-on delay and shorter rise time. Table 8. Soft Start Ramp Timing VS_A/VS_B Reference Ramp Rate Channel C Duty Cycle Ramp Rate 1 V/1.75 ms 40 ns/1 switching cycle 1 V/10.5 ms 40 ns/2 switching cycles 1 V/21.0 ms 40 ns/4 switching cycles 1 V/40.2 ms 40 ns/8 switching cycles For the unregulated Channel C, the duty cycle can be pro- grammed to increase or decrease at a rate set by Bits[5:4] of Register 0xFE68. The duty cycle variation can be set to 40 ns per one, two, four, or eight switching cycles. The soft start time for Channel C is usually faster than the soft start time for the regulated channels. Two variation values are used for Channel C soft start: tSS_C1 = |tF1 − tR1| tSS_C2 = |tF2 − tR2| where: tR1 and tR2 are the timing values for the rising edges of OUT1 and OUT2, respectively. tF1 and tF2 are the timing values for the falling edges of OUT1 and OUT2, respectively. tSS_C1 sets the variation for OUT1, OUT3, OUT5, and OUT7 if these PWM outputs are assigned to Channel C. tSS_C2 sets the variation for OUT2, OUT4, OUT6, and OUT8 if these PWM outputs are assigned to Channel C. Both edges of a PWM signal assigned to Channel C can implement modulation during soft start. At the initiation of soft start, a modulated edge assigned to Channel C behaves as follows: • If the edge is configured for positive modulation, the edge timing is the preset value plus the variation value. During soft start, the edge moves to the left until it reaches the preset value. • If the edge is configured for negative modulation, the edge timing is the preset value minus the variation value. During soft start, the edge moves to the right until it reaches the preset value. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |