| поискавой системы для электроныых деталей |
|
AD9557/PCBZ датащи(PDF) 35 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9557/PCBZ датащи(HTML) 35 Page - Analog Devices |
|
35 / 92 page ![]() Data Sheet AD9557 Rev. A | Page 35 of 92 OUTPUT PLL (APLL) A diagram of the output PLL (APLL) is shown in Figure 39. LF CAP VCO2 3.35GHz TO 4.05GHz PFD FROM DPLL TO CLOCK DISTRIBUTION LF CP INTEGER DIVIDER OUTPUT PLL DIVIDER (APLL) ÷N2 Figure 39. Output PLL Block Diagram The APLL provides the frequency upconversion from the DPLL output to the 3.35 GHz to 4.05 GHz range, while also providing noise filtering on the DPLL output. The APLL reference input is the output of the DPLL. The feedback divider is an integer divider. The loop filter is partially integrated with the one external 6.8 nF capacitor. The nominal loop bandwidth for this PLL is 250 kHz, with 68 degrees of phase margin. The frequency wizard that is included in the evaluation software configures the APLL, and the user should not need to make changes to the APLL settings. However, there may be special cases where the user may wish to adjust the APLL loop bandwidth to meet a specific phase noise requirement. The easiest way to change the APLL loop BW is to adjust the APLL charge pump current in Register 0x0400. There is sufficient stability (680 of phase margin) in the APLL default settings to permit a broad range of adjustment without causing the APLL to be unstable. The user should contact Analog Devices directly if more detail is needed. Calibration of the APLL must be performed at startup and whenever the nominal input frequency to the APLL changes by more than ±100 ppm, although the APLL maintains lock over voltage and temperature extremes without recalibration. Calibration centers the dc operating voltage at the input to the APLL VCO. APLL calibration at startup can be accomplished during initial register loading by following the instructions in the Device Register Programming Using a Register Setup File section of this datasheet. To recalibrate the APLL VCO after the chip has been running, the user should first input the new settings (if any). Ensure that the system clock is still locked and stable, and that the DPLL is in free run mode with the free run tuning word set to the same output frequency that is used when the DPLL is locked. Use the following steps to calibrate the APLL VCO: 1. Ensure that the system clock is locked and stable. 2. Ensure that the DPLL is in user free run mode (Register 0x0A01[5] = 1b), and the free run tuning word is set. 3. Write Register 0x0405 = 0x20. 4. Write Register 0x0005 = 0x01. 5. Write Register 0x0405 = 0x21. 6. Write Register 0x0005 = 0x01. 7. Monitor the APLL status using Bit 2 in Register 0x0D01. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |