| поискавой системы для электроныых деталей |
|
MPF0900AMBA2ES датащи(PDF) 91 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MPF0900AMBA2ES датащи(HTML) 91 Page - NXP Semiconductors |
|
91 / 205 page ![]() NXP Semiconductors PF09 Nine-channel power management IC with advanced system safety monitoring VDIG_OV_S VDIG overvoltage status 0 No OV detected 1 OV detected Table 106. VDIG overvoltage status 13.1.3 Internal bandgap references The PF09 is provided with two fully independent bandgap references as part of the functional safety architecture. The first bandgap regulator is dedicated to providing a voltage reference for the output voltage generation, and it is referred to as main bandgap through this document. The second bandgap regulator is used to provide a voltage reference to the OV/UV monitors, as well as other safety related blocks, and it is referred to as monitoring bandgap throughout this document. 13.2 System voltage generation 13.2.1 VAON The VAON regulator is a standalone low-power LDO with low dropout operation. It supports an Always-on mode to provide voltage to the low-power domains intended to remain on during the PMIC off states. The VAON supports configurable output voltage with nominal current of 10 mA. The VAON output is programmable to 1.8 V, 3.0 V or 3.3 V with up to +/- 2% accuracy. VAON[1:0] VAON output voltage (V) 00 Off 01 1.8 10 3.0 11 3.3 Table 107. VAON output voltage By default, the VAON regulator uses the OTP_VAON[1:0] bits to set the initial voltage configuration as soon as power is applied. The VAON can be configured in two different modes of operation based on the value of the OTP_VAON[1:0] and the OTP_VAON_SEQ[7:0] bits. OTP_VAON[1:0] OTP_VAON_SEQ[7:0] Mode Control 00 Don’t care System regulator Default off (enabled via I2C) 01, 10, 11 0x00 Always-on regulator Enabled after fuse load 01, 10, 11 Not 0x00 System regulator Enabled in Power- up sequence Table 108. VAON modes 13.2.1.1 Always-on mode When power is applied for the first time, the PF09 will perform an initial configuration cycle to load the OTP configuration of the VAON regulator. If the VAON is set as an Always-on regulator, the VAON output will be enabled after fuse load. PF09 All information provided in this document is subject to legal disclaimers. © 2026 NXP B.V. All rights reserved. Product data sheet Rev. 1.3 — 16 December 2025 Document feedback 91 / 205 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |