MPF0900AMBA2ES датащи(PDF) 57 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MPF0900AMBA2ES датащи(HTML) 57 Page - NXP Semiconductors |
|
57 / 205 page ![]() NXP Semiconductors PF09 Nine-channel power management IC with advanced system safety monitoring aaa-056062 RSTB PGOOD (optional) REG4_PG REG4 REG3_PG REG3 REG2_PG REG2 REG1_PG REG1 2 ms (max) recovery Reg power down SEQ SLOT 1 SEQ SLOT 2 SEQ SLOT 3 PWRUP fail PG’s NOK POWER-UP FAILURE WITH PERSISTENT FAULT CONDITION Figure 17. Power-up failure with persistent fault condition After the RSTB is released, an OV/UV or ILIM condition will trigger a fault detection and protection mechanism as described in section Section 12.6.2. If a regulator fault occurs after RSTB is released but before the Power-up sequence is finalized, the Power-up sequence will continue to power up if the fault condition is not enough to start a hard fault, based on the fault management rules during the SYSTEM ON states. During the Power-up sequence, the PGOOD pin will be used as an external indicator of an OV/UV failure when the RSTB is ready to be de-asserted, since the PG_EN bits for all regulators are reset to 1 at power up. When the OTP_PWRUP_CHK = 1, the RSTB must be set to release at a later slot than any of the voltage regulators needed by the system before going out of the reset condition. This will allow sufficient time for all regulators to reach their corresponding regulation point during the power-up sequence and avoid false fault conditions due to the regulators ramping up too slowly. When the RSTB pin is intended to be released before all of the switching and LDO regulators, the OTP_PWRUP_CHK bit should always be set to 0, to prevent the system from generating a power-up failure event. When OTP_PWRUP_CHK = 1, if any IO is used as a GPOx, it may be released at any time in the Power-up sequence, as long as the RSTB does not try to release before there is an actual regulator enabled to check for a power good condition (system-level configuration). 12.6.5 Fault monitoring during dynamic power up When operating in dynamic power-up, the PF09 will start monitoring for OV and UV conditions as soon as the regulator is enabled. If an OV/UV condition is detected while the Power-up sequence is in progress, such condition will be used as a gating factor to prevent the regulator on the next hierarchical level from turning on until all regulators enabled previously are in regulation. When regulators in the next hierarchical level are enabled, the settling timer is restarted to allow the new regulators to ramp up and reach regulation. PF09 All information provided in this document is subject to legal disclaimers. © 2026 NXP B.V. All rights reserved. Product data sheet Rev. 1.3 — 16 December 2025 Document feedback 57 / 205 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |