MPF0900AMBA2ES датащи(PDF) 59 Page - NXP Semiconductors

номер детали MPF0900AMBA2ES
подробное описание детали  Nine-channel power management IC with advanced system safety monitoring
PDF  205 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  NXP [NXP Semiconductors]
домашняя страница  http://www.nxp.com
Logo NXP - NXP Semiconductors

MPF0900AMBA2ES датащи(HTML) 59 Page - NXP Semiconductors

Back Button MPF0900AMBA2ES Datasheet HTML 55Page - NXP Semiconductors MPF0900AMBA2ES Datasheet HTML 56Page - NXP Semiconductors MPF0900AMBA2ES Datasheet HTML 57Page - NXP Semiconductors MPF0900AMBA2ES Datasheet HTML 58Page - NXP Semiconductors MPF0900AMBA2ES Datasheet HTML 59Page - NXP Semiconductors MPF0900AMBA2ES Datasheet HTML 60Page - NXP Semiconductors MPF0900AMBA2ES Datasheet HTML 61Page - NXP Semiconductors MPF0900AMBA2ES Datasheet HTML 62Page - NXP Semiconductors MPF0900AMBA2ES Datasheet HTML 63Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 59 / 205 page
background image
NXP Semiconductors
PF09
Nine-channel power management IC with advanced system safety monitoring
12.7 System diagnostics
12.7.1 System fault flags
The PF09 provides dedicated flags to improve the system diagnostics when fault, reset or turn-off conditions
have been detected.
System diagnostic flags can be cleared manually by writing a 1 to the corresponding bit, and the values of the
flags will remain unchanged as long as the digital supply (VDIG) does not cross the internal POR threshold. The
following scenarios will cause a loss of the internal VDIG, hence a loss of the system fault flag:
• VIN goes below the VIN_POR threshold
• The device is in the ULPOFF state.
• VDIG supply is shorted externally (fault condition)
Table 56 provides a summary of the system diagnostic faults available in the PF09 devices.
Diagnostic flag
Description
DCRC_FLG
Flag is set when a dynamic CRC error is present
DFS_FLG
Flag is set when device is waking up from the DFS state
VIN_OV_FLG
Flag is set when a VIN_OV condition is present
XFAIL_FLG
Flag is set when a power-down event was initiated via the XFAILB pin.
WD_FLG
Flag is set when a watchdog reset event is initiated.
XRESET_FLG
Flag is set when an external reset is requested via the XRESET or FCCU blocks
SFAULT_FLG
Flag is set when a soft fault is present (OV/UV/ILIM)
HFAULT_FLG
Flag is set when a hard fault is present.
Table 56. System diagnostic flags
The hard-fault event has dedicated flags to trace the source of failure.
Hard-fault Flag
Description
UVDET_FAIL
This flag is set automatically when the device crosses the UVDET threshold in the rising
edge, to indicate the device is waking up from the DFS state after a VIN < UVDET condition.
RSTB_FAIL
The RSTB is externally held low for longer than the OTP_RSTB_TSHORT[1:0]
PU_FAIL
A power-up failure started the hard fault.
RESET_FAIL
The Reset counter reaches the maximum number of events allowed. (RESET_CNT[3:0] =
RESET_MAX[3:0])
FLTCNT_FAIL
The Fault counter reaches the maximum number of failures allowed. (FAULT_CNT[3:0] =
FAULT_MAX_CNT)
REG_FAIL
A fault condition in a regulator causes a hard fault. (Fault timer, VAON UV not
acknowledged)
TSD_FAIL
A power-down sequence is initiated due to a thermal shutdown event.
Table 57. Hard-fault Flags
The MCU is able to read the fault flags during the system-on states in order to obtain information about the
previous failure, provided the state machine is able to power up successfully after such a failure.
PF09
All information provided in this document is subject to legal disclaimers.
© 2026 NXP B.V. All rights reserved.
Product data sheet
Rev. 1.3 — 16 December 2025
Document feedback
59 / 205



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com