| поискавой системы для электроныых деталей |
|
M16C/26 датащи(PDF) 203 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
M16C/26 датащи(HTML) 203 Page - Renesas Technology Corp |
|
203 / 239 page ![]() CPU Rewrite Mode (Flash Memory Version) 197 Renesas Technology Corp. M16C/26 Group SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER Under development Preliminary Specifications Rev. 0.9 Specifications in this manual are tentative and subject to change. Start Write 4016 Program completed Write data to target address SR4=0? Program error NO YES Status register read NO YES SR7=1? or RY/BY=1? (Set an address to even address in the user ROM area when reading the status register) (Set an address to even address in the user ROM area when write 4016 ) Figure 1.20.3. Program flowchart Program Command (4016) Program operation starts when the command code “4016” is written in the first bus cycle. Then, if the address and data to program are written in the 2nd bus cycle, program operation (data programming and verification) will start. Make an address in the first bus cycle same as an address to program by the second bus cycle. Whether the write operation is completed can be confirmed by reading the status register or the RY/ BY status flag. When the program starts, the read status register mode is accessed automatically and the content of the status register is read into the data bus (D0 - D7). The status register bit 7 (SR7) is set to 0 at the same time the write operation starts and is returned to 1 upon completion of the write operation. In this case, the read status register mode remains active until the Read Array command (FF16) is written. The RY/BY status flag is 0 during write operation and 1 when the write operation is completed as is the status register bit 7. At program end, program results can be checked by reading the status register. Figure 1.20.3 shows an example of a program flowchart. Each block of the flash memory can be write protected by using a lock bit. For details, refer to the section where the data protect function is detailed. Additional writes to the already programmed pages are prohibited. Do a command to use in right after of program command as follows Make an address in the first bus cycle same as an address to program by the second bus cycle of program command. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |