| поискавой системы для электроныых деталей |
|
BLUENRG-2 датащи(PDF) 33 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
BLUENRG-2 датащи(HTML) 33 Page - STMicroelectronics |
|
33 / 190 page ![]() BlueNRG-2 Functional details DocID030675 Rev 2 33/190 Table 30: Output data rate with microphone DIG_FILT_CLK OSR Output data rate [Ksample/s] 1 (clock = 0.8 MHz) 0 (200) 4 1 (100) 8 2 (64) 12.5 3 (32) 25 0 (clock = 1.6 MHz) 0 (200) 8 1 (100) 16 2 (64) 25 3 (32) 50 3.6.2.1 ADC start conversion The ADC both analog and digital sub-system are switched on by setting ADCON and SWSTART. The conversion operation consists of four phases. 1. The wake-up phase lasts 5 us, is present at the beginning of a single acquisition, with the goal to let the analog system to settle before to start the acquisition. 2. If the CALEN is set, a calibration phase is performed. It permits to compensate the offset in the analog part. The conversion status is tracked by SR status register. At the beginning of the conversion the BUSY bit is set and masks any attempt to change CONF, up to the end of the conversion. At end of this conversion, the ENDCAL flag is generated and the OFFSET register is written with the converted offset voltage. 3. The acquisition phase is regulated by a timeout depending on the resolution. In this phase, digital filter chain processes the data coming from ADC. 4. The elaboration phase is at the end of the timeout, the data obtained at the output of the digital filter is written in the DATA register. If the calibration is on, the output of the digital filter is de-embedded considering the content of the OFFSET register. Furthermore, the ADCEOC flag is generated to warn about the end of conversion. If ENAB_COMP bit is set, the WDOG flag is generated to warn that the result of the conversion is between a high THRESHOLD_HI and low threshold THRESHOLD_LO. It is always advisable to set the register field CALEN in order to perform automatic calibration for each measurement. 3.6.2.2 ADC offset The ADC can automatically correct the offset error. To enable the automatic offset correction the CALEN and the OFFSET_UPDATE must be set. The result of the last calibration is stored in the OFFSET register. The correction of the offset can be also done manually, for example by making a conversion of the internal channel InP = InN = 0.6 V and after that, writing the result of conversion in the OFFSET register. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |