113 / 140 page ![]() Data Sheet ADP1055 Rev. A | Page 113 of 140 Bits Bit Name R/W Description [3:2] VOUT_OV sampling R/W Bit 3 Bit 2 Sampling 0 0 One sample sets the VOUT_OV flag (80 μs sampling period) 0 1 Two consecutive samples that read a value greater than the one set in VOUT_OV_FAULT_LIMIT set the VOUT_OV flag (160 μs sampling period) 1 0 Three consecutive samples that read a value greater than the one set in VOUT_OV_FAULT_LIMIT set the VOUT_OV flag (240 μs sampling period) 1 1 Four consecutive samples that read a value greater than the one set in VOUT_OV_FAULT_LIMIT set the VOUT_OV flag (320 μs sampling period) [1:0] Reserved Reserved Table 191. Register 0xFE4E—CS1_SETTING Bits Bit Name R/W Description 7 Reserved R Reserved. [6:4] CS1 fast OCP blanking R/W Set the CS1 fast OCP blanking time to 0 ns, 40 ns, 80 ns, 120 ns, 200 ns, 400 ns, 600 ns, or 800 ns. 3 CS1 fast OCP bypass R/W Setting this bit means that the GPIO1 pin is used for CS1 fast OCP instead of the CS1 pin. [2:0] CS1 fast OCP timeout R/W Set the number of consecutive switching cycles with a CS1 OCP condition before the IIN_OC_FAST_FAULT flag is set: 1, 4, 16, 128, 256, 384, 512, or 1024. Table 192. Register 0xFE4F—CS2_SETTING Bits Bit Name R/W Description 7 CC turbo mode R/W Reduces the CS2 average time from 328 μs to 41 μs for CC mode. [6:4] CS2 fast OCP timeout R/W Sets the number of consecutive switching cycles with a CS2 OCP condition before the IOUT_OC_FAST_FAULT flag is set: 1, 4, 16, 128, 256, 384, 512, or 1024. 3 Peak constant current mode R/W When this bit is set, CS2 fast OCP cycle-by-cycle protection on OUTA to OUTD is disabled. The CS2 fast OCP timeout is still active. 2 Average constant current disable R/W 0 = average constant current mode is enabled/disabled, as defined by PMBus. Threshold = IOUT_OC_FAULT_LIMIT. ILIM = IOUT_OC_FAULT_LIMIT × (100 + percentage), where percentage and polarity are defined in Register 0xFE5D[3:0]. The current fault response is PMBus compliant. 1 = average constant current mode is always on (not PMBus compliant). Threshold = ILIM = IOUT_OC_FAULT_LIMIT × (100 ± percentage), where percentage and polarity are defined in Register 0xFE5D[3:0]. Current fault response defaults to these settings (Response Bits[7:6]). 00 = ignore fault. 01 = ignore fault. 10 = ignore fault. 11 = shut down, disable the output, and respond as programmed in retry setting (Bits[5:3]). [1:0] CS2 range R/W Sets the CS2 ADC range. Bit 1 Bit 0 ADC Range (mV) 0 0 30 (low-side sensing) 0 1 60 (low-side sensing) 1 0 480 (high-side sensing) 1 1 Reserved |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |