ADP1055ACPZ-R7 датащи(PDF) 68 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1055ACPZ-R7 датащи(HTML) 68 Page - Analog Devices |
|
68 / 140 page ![]() ADP1055 Data Sheet Rev. A | Page 68 of 140 IOUT_OC_FAULT_LIMIT The IOUT_OC_FAULT_LIMIT command sets the threshold value (in amperes) measured at the sense pins that causes an overcurrent fault condition. Table 44. Register 0x46—IOUT_OC_FAULT_LIMIT Bits Bit Name R/W Description [15:11] Exponent-N R/W Twos complement N-exponent used in linear data format (X = Y × 2N). [10:0] Mantissa-Y R/W Twos complement Y-mantissa used in linear data format (X = Y × 2N). IOUT_OC_FAULT_RESPONSE The IOUT_OC_FAULT_RESPONSE command instructs the device on actions to take due to an output overcurrent fault condition. The device notifies the host and sets the IOUT_OC_FAULT bit in the STATUS_BYTE register, the IOUT bit in the STATUS_WORD register, and the IOUT_OC_FAULT bit in the STATUS_IOUT register. Table 45. Register 0x47—IOUT_OC_FAULT_RESPONSE Bits Bit Name R/W Description [7:6] Response R/W Determines the device response to an overcurrent fault condition. Bit 7 Bit 6 Response 0 0 Operate in current limiting mode, maintaining the output current at IOUT_OC_FAULT_LIMIT. 0 1 Operate in current limiting mode, maintaining the output current at IOUT_OC_FAULT_LIMIT. If VOUT falls below the IOUT_OC_LV_FAULT_LIMIT, respond as programmed by the retry setting (Bits[5:3]). 1 0 Continue operation in current limiting mode for the delay time (Bits[2:0]). If the device is still in current limiting mode, respond as programmed by the retry setting (Bits[5:3]). 1 1 Shut down, disable the output, and respond as programmed by the retry setting (Bits[5:3]). [5:3] Retry setting R/W Number of retry attempts following a fault condition. A fault condition can be cleared by a reset, a power-off/power-on sequence, or a loss of bias power. Bit 5 Bit 4 Bit 3 Number of Retries 0 0 0 0 0 0 1 1 0 1 0 2 0 1 1 3 1 0 0 4 1 0 1 5 1 1 0 6 1 1 1 Infinite [2:0] Delay times R/W Number of delay time units (see Register 0xFE3E). IOUT_OC_LV_FAULT_LIMIT The IOUT_OC_LV_FAULT_LIMIT command sets the lower voltage threshold (in volts) measured at the sense/output pin that causes an undervoltage-in-CLM fault condition. This limit applies only when the device is operating in current limiting mode (CLM). Table 46. Register 0x48—IOUT_OC_LV_FAULT_LIMIT Bits Bit Name R/W Description [15:0] Mantissa-Y R/W Unsigned Y-mantissa used in output voltage related commands in linear data format (V = Y × 2N). N is specified by VOUT_MODE[4:0]. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |