| поискавой системы для электроныых деталей |
|
ADP1055ACPZ-R7 датащи(PDF) 76 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1055ACPZ-R7 датащи(HTML) 76 Page - Analog Devices |
|
76 / 140 page ![]() ADP1055 Data Sheet Rev. A | Page 76 of 140 POUT_OP_FAULT_RESPONSE The POUT_OP_FAULT_RESPONSE command instructs the device on the actions to take due to an output overpower fault condition. The device notifies the host and sets the IOUT_OC_FAULT bit in the STATUS_BYTE register, the IOUT/POUT bit in the STATUS_WORD register, and the POUT_OP_FAULT bit in the STATUS_IOUT register. Table 70. Register 0x69—POUT_OP_FAULT_RESPONSE Bits Bit Name R/W Description [7:6] Response R/W Determines the device response to an overpower fault condition. Bit 7 Bit 6 Response 0 0 Do nothing. 0 1 Continue operation for the delay time (Bits[2:0]). If the fault persists, retry the number of times specified by Bits[5:3]. 1 0 Shut down, disable the output, and respond as programmed in the retry setting (Bits[5:3]). 1 1 Disable the output while the fault is present. Operation resumes and the output is enabled when the fault condition no longer exists. [5:3] Retry setting R/W Number of retry attempts following a fault condition. A fault condition can be cleared by a reset, a power-off/power-on sequence, or a loss of bias power. Bit 5 Bit 4 Bit 3 Number of Retries 0 0 0 0 0 0 1 1 0 1 0 2 0 1 1 3 1 0 0 4 1 0 1 5 1 1 0 6 1 1 1 Infinite [2:0] Delay times R/W Number of delay time units (see Register 0xFE3E). STATUS_BYTE The STATUS_BYTE register returns the lower byte of the STATUS_WORD register. A value of 1 in this command indicates that a fault has occurred. As per the PMBus standard, the BUSY bit is writable to allow the user to clear that latched bit using a write command with a 1 to Bit 7, similar to other STATUS_xxx commands. The other bits in this register cannot be cleared with a write to the STATUS_BYTE command, but should be cleared with a write to the STATUS_VOUT, STATUS_IOUT, STATUS_INPUT, STATUS_TEMP, or STATUS_CML command. Table 71. Register 0x78—STATUS_BYTE Bits Bit Name R/W Description 7 BUSY R/W This bit is asserted if the device is busy and unable to respond. 6 POWER_OFF R This bit is asserted if the unit is not providing power to the output. 5 VOUT_OV_FAULT R An output overvoltage fault has occurred. 4 IOUT_OC_FAULT R An output overcurrent fault has occurred. 3 VIN_UV_FAULT R An input undervoltage fault has occurred. 2 TEMPERATURE R A temperature fault or warning has occurred. 1 CML R A communications, memory, or logic fault has occurred. 0 NONE_OF_THE_ABOVE R A fault or warning not listed in Bits[7:1] has occurred. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |