| поискавой системы для электроныых деталей |
|
SC28L201 датащи(PDF) 46 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
SC28L201 датащи(HTML) 46 Page - NXP Semiconductors |
|
46 / 110 page ![]() 9397 750 13138 © Koninklijke Philips Electronics N.V. 2005. All rights reserved. Product data sheet Rev. 01 — 31 October 2005 46 of 110 Philips Semiconductors SC28L201 3.3 V, 5 V UART, 3.125 Mbit/s, with 256-byte FIFO 8.2.3 Mode Register 2 (MR2) MR2 can be accessed directly at 0x22 in the Extended section of the address map, or by means of the MR Pointer at 0x00 used by legacy code. The MR2 register provides basic channel setup control that may need more frequent updating. Table 18: MR2 - Mode Register 2 (address 0x22) bit description Bit Symbol Description 7:6 Channel Mode Select. The UART can operate in one of the following four modes: 00 = Normal mode (default) 01 = Automatic Echo mode 10 = Local loopback mode 11 = Remote loopback mode Normal mode: the transmitter and receiver operating independently. Automatic Echo mode: this mode automatically retransmits the received data. The following conditions are true while in Automatic Echo mode: • Received data is re-clocked and re-transmitted on the TXD output. • The receiver clock is used for the transmitted data. • The receiver must be enabled, but the transmitter need not be enabled. • The TxRDY and Tx Idle status bits are inactive. • The received parity is checked, but is not regenerated for transmission, that is, transmitted parity bit is as received. • Character framing is checked, but the stop bits are retransmitted as received. Rx data is sent to RxFIFO. • A received break is echoed as received until the next valid start bit is detected. • CPU to receiver communication continues normally, but the CPU to transmitter link is disabled. Local loopback mode. In this mode: • The transmitter output is internally connected to the receiver input. • The transmitter’s 1 × clock is used for the receiver. • The TXD output is held HIGH. • The RXD input is ignored. • The transmitter must be enabled, but the receiver need not be enabled. • CPU to transmitter and receiver communications continue normally. Remote Loopback diagnostic mode. In this mode: • Received data is re-clocked and re-transmitted on the TXD output. • The receiver 1 × clock is used for the transmitted data. • Received data is not sent to the local CPU, and the error status conditions are inactive. • The received parity is not checked and is not regenerated for transmission, that is, the transmitted parity bit is as received. • The receiver must be enabled, but the transmitter need not be enabled. • Character framing is not checked, and the stop bits are retransmitted as received. • A received break is echoed as received until the next valid start bit is detected. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |