32 / 124 page ![]() AD9154 Data Sheet Rev. C | Page 32 of 124 Use the list of delay values to calculate LMFCDel and LMFCVar, but note that some of the delay values may need to be remapped first. The maximum possible value for DYN_LINK_LATENCY_x is one less than the number of PClocks in a multiframe (PClocksPerMF). A rollover condition may be encountered, meaning the set of recorded delay values may roll over the edge of a multiframe. If so, Delay values may be near both 0 and PClocksPerMF. If this occurs, add PClocksPerMF to the set of values near 0. For example, for Delay value readbacks of 6, 7, 0, and 1, the 0 and 1 Delay values must be remapped to 8 and 9, making the new set of Delay values 6, 7, 8, and 9. Across power cycles, links, and devices, • MinDelay is the minimum of all delay measurements. • FALL_COUNT_Delay is the maximum of all delay measurements. For safety, add a guard band of 1 PClock cycle to each end of the link delay and calculate LMFCVar and LMFCDel with the following equation: LMFCVar = (FALL_COUNT_Delay + 1) − (MinDelay − 1) Note that if LMFCVar must be more than 10, the AD9154 cannot tolerate the variable delay in the system. For Subclass 1, LMFCDel = ((MinDelay − 1) × PClockFactor) % K For Subclass 0 LMFCDel = (MinDelay − 1) % PClockPerMF Program the same LMFCDel and LMFCVar across all links and devices. See the Link Delay Setup Example, Without Known Delay section for an example calculation. CROSSBAR SETUP Registers 0x308 to Register 0x30B allow arbitrary mapping of physical lanes (SERDINx±) to logical lanes used by the SERDES deframers. Table 33. Crossbar Registers Address Bits Logical Lane 0x308 [2:0] XBARVAL0 0x308 [5:3] XBARVAL1 0x309 [2:0] XBARVAL2 0x309 [5:3] XBARVAL3 0x30A [2:0] XBARVAL4 0x30A [5:3] XBARVAL5 0x30B [2:0] XBARVAL6 0x30B [5:3] XBARVAL7 Write each XBARVALy with the number (x) of the desired physical lane (SERDINx±) from which to get data. By default, all logical lanes use the corresponding physical lane as their data source. For example, by default, XBARVAL0 = 0, meaning Logical Lane 0 receives data from Physical Lane 0 (SERDIN0±). If instead the user wants to use SERDIN4± as the source for Logical Lane 0, the user must write XBARVAL0 = 4. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |