123 / 140 page ![]() Data Sheet ADP1055 Rev. A | Page 123 of 140 Table 226. Register 0xFE8F—FAULT_TEMPERATURE Bits Bit Name R/W Description [7:0] FAULT_TEMPERATURE R Unlatched fault conditions after debounce (see STATUS_TEMPERATURE for latched version) Table 227. Register 0xFE90—FAULT_CML Bits Bit Name R/W Description [7:0] FAULT_CML R Unlatched fault conditions after debounce (see STATUS_CML for latched version) Table 228. Register 0xFE91—FAULT_OTHER Bits Bit Name R/W Description [7:0] FAULT_OTHER R Unlatched fault conditions after debounce (see STATUS_OTHER for latched version) Table 229. Register 0xFE92—FAULT_MFR_SPECIFIC Bits Bit Name R/W Description [7:0] FAULT_MFR_SPECIFIC R Unlatched fault conditions after debounce (see STATUS_MFR_SPECIFIC for latched version) Table 230. Register 0xFE93—FAULT_UNKNOWN Bits Bit Name R/W Description [15:0] FAULT_UNKNOWN R Unlatched fault conditions after debounce (see STATUS_UNKNOWN for latched version) Table 231. Register 0xFE94—STATUS_UNKNOWN Bits Bit Name R/W Description 15 EEPROM unlocked R/W The EEPROM is unlocked. 14 Adaptive dead time R/W Adaptive dead time threshold has been crossed. 13 Soft start filter R/W The soft start filter is in use. 12 Soft start ramp or soft stop ramp R/W The reference is being ramped up (soft start) or ramped down (soft stop). 11 Modulation limit R/W Modulation is at its minimum or maximum limit. 10 Volt-second and duty balance limit R/W Volt-second balance or duty balance at is the maximum/minimum limit. 9 Light load mode R/W The device is in light load mode. 8 Constant current R/W Power supply is operating in constant current mode (constant current mode is enabled). 7 PGOOD2 fault R/W PGOOD2 fault. At least one of the flags listed in Register 0xFE45 has been set (see Table 182). 6 PGOOD1 fault R/W PGOOD1 fault. At least one of the flags listed in Register 0xFE44 has been set (see Table 181). 5 Sync unlock R/W Sync mode is enabled, but unit not locked to sync input frequency. 4 SR off R/W Synchronous rectifiers SR1 and SR2 are disabled. This flag is set when one of the following cases is true: SR1 and SR2 are disabled by the user; the load current has fallen below the threshold in Register 0xFE4B[7:5]; a fault has been set that was configured to disable the synchronous rectifiers; or SR outputs are blanked during soft start and during a pulse skip condition. 3 Address warning R/W I2C/PMBus address warning. ADD resistor value out-of-range. 2 VCORE OV R/W 2.5 V VCORE is above limit. Action is set to immediate shutdown. 1 VDD OV R/W VDD is above limit. The I2C interface stays functional, but a unit power-off/power-on sequence is required to restart the power supply. The response to a VDD overvoltage is programmable in Register 0xFE4D[6]. 0 VDD UV R/W VDD is below limit. The response to a VDD undervoltage immediate shutdown. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |