| поискавой системы для электроныых деталей |
|
AD9549 датащи(PDF) 51 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9549 датащи(HTML) 51 Page - Analog Devices |
|
51 / 78 page ![]() Preliminary Technical Data AD9549 Rev. PrA Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibilityis assumedbyAnalogDevicesforitsuse,norforanyinfringements of patents or other rightsofthirdpartiesthatmayresultfromitsuse.Specificationssubjecttochangewithoutnotice.No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarksandregisteredtrademarksarethepropertyoftheirrespectiveowners. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 www.analog.com Fax: 781.461.3113 ©2007 Analog Devices, Inc. All rights reserved. POWER-ON RESET On initial power-up, the AD9549 internally generates a 75ns RESET pulse. The pulse is initiated when both of the following two conditions are met: The 3.3v supply is greater than 2.35± 0.1V The 1.8v supply is greater than 1.4± 0.05V Less than 1 ns after RESET goes high, the S1-S4 configuration pins go high impedance, and remain high impedance until RESET is deactivated. This allows strapping and configuration during RESET. Because of this reset sequence, power supply sequencing isn’t critical. AD9549 POWER UP AND PROGRAMMING SEQUENCE The following sequence should be followed when initializing the AD9549: 1. Apply Power. The AD9549 will perform an internal reset. 2. IMPORTANT: Make sure the desired configuration registers have Single Tone mode(R0100[5]) set, and Lock Loop (R0100[0]) cleared. If the Lock Loop bit is set on initial loading, the AD9549 will attempt to lock the loop before it has been configured. 3. Once the registered are loaded, the OOL (Out of limits) and LOR (loss of reference) can be monitored to insure that a valid reference signal is present on RefA or RefB. 4. If a valid reference is present, Register 0100 can be reprogrammed to clear Single Tone Mode and lock the loop. 5. Automatic Holdover mode can now be used to make the AD9549 immune to any disturbance on the reference inputs. The following sequence should be followed when changing frequencies the AD9549: 1. Open the loop and enter single tone mode via Register 0100. 2. Enter the new register settings. 3. Write 1E to Register 0012. 4. Once the registered are loaded, the OOL (Out of limits) and LOR (loss of reference) can be monitored to insure that a valid reference signal is present on RefA or RefB. 5. If a valid reference is present, Register 0100 can be reprogrammed to clear Single Tone Mode and lock the loop. 6. Automatic Holdover mode can now be used to make the AD9549 immune to any disturbance on the reference inputs. Notes: Attempting to lock the loop without a valid reference can put the AD9549 into a state that requires a reset. Automatic Holdover mode is not available unless the loop has been successfully closed. If the user desires to open and close the loop manually, we recommend writing 1E to Register 0012 prior to reclosing the loop. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |