96 / 113 page ![]() ADP1052 Data Sheet Rev. B | Page 96 of 113 Figure 67 and Register 0xFE3C in Table 159 describe the modulation limit settings. tRX tFX tRY tFY t0, START OF SWITCHING CYCLE tS/2 tS, END OF SWITCHING CYCLE 3 tS/2 OUTx OU TY tMODU_LIMIT tMODU_LIMIT Figure 67. Setting Modulation Limits Table 159. Register 0xFE3C—Modulation Limit Bits Bit Name/Function R/W Description [7:0] Modulation limit R/W This register sets the modulation limit, tMODU_LIMIT (maximum duty cycle). The modulation limit is the maximum time variation for the modulated edges from the default timing (see Figure 67). The step size of an LSB depends on the switching frequency. Switching Frequency Range (kHz) LSB Step Size (ns) 49 to 87 80 97.5 to 184 40 195.5 to 379 20 390.5 to 625 10 Table 160. Register 0xFE3D—Feedforward and Soft Start Filter Gain Bits Bit Name/Function R/W Description 7 Soft start enable of open-loop input voltage feedforward operation R/W Setting this bit enables the soft start procedure of the open-loop input voltage feedforward operation. If this function is used, set Bit 6. 6 Open-loop input voltage feedforward operation enable R/W 0 = open-loop input voltage feedforward operation is disabled. 1 = open-loop input voltage feedforward operation is enabled. 5 High frequency ADC debounce time R/W This bit sets the debounce time for detecting the settling of the VS high frequency ADC. Bit 4 must be set to 1 to enable this function. 0 = 5 ms debounce time. 1 = 10 ms debounce time. 4 High frequency ADC debounce enable R/W Setting this bit enables a debounce time for detecting the settling of the VS high frequency ADC at the end of a soft start. The debounce time is set using Bit 5. 3 Feedforward ADC selection R/W Always set this bit to select the 11-bit VF ADC (factory default setting). 2 Feedforward enable R/W This bit enables or disables feedforward control during closed-loop operation. 0 = closed-loop input voltage feedforward control is disabled. 1 = closed-loop input voltage feedforward control is enabled. [1:0] Soft start filter gain R/W These bits set the soft start gain of the soft start filter. Bit 1 Bit 0 Soft Start Filter Gain 0 0 1 0 1 2 1 0 4 1 1 8 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |