31 / 113 page ![]() Data Sheet ADP1052 Rev. B | Page 31 of 113 Manufacturer Specific Latched Flags The ADP1052 has a set of latched flag registers (Register 0xFEA3 to Register 0xFEA5). The latched flag registers have the same flags as Register 0xFEA0 to Register 0xFEA2, but the flags in the latched registers remain set so that intermittent faults can be detected. Reading a latched flag register resets all the flags in that register. A PSON signal can also reset the latched flags. Flags Debounce Time The debounce timing of the manufacturer specific flags and the PMBus standard flags is programmable (see Table 6). The debounce time is the time during which the fault condition must be continuously triggered before the flag is set. Refer to the corresponding register settings for more information. The debounce time is used for flag setting. Only the PGOOD flag has a debounce time for flag clearing. For all other flags, the flag reenable delay, specified in Register 0xFE05[7:6] (see Table 113), functions as the debounce time for flag clearing. Refer to the Manufacturer Specific Protection Responses section for details. Housekeeping Flags The CHIP_PASSWORD_UNLOCKED flag (Register 0xFEA0[7]) indicates that the chip password is in the unlocked state, and all the registers can be accessed. The VDD_OV flag (Register 0xFEA0[0]) is set when the VDD voltage exceeds the VDD OVLO threshold. The debounce time is programmable as 2 μs or 500 μs, using Register 0xFE05[4]. When the flag is set, the ADP1052 shuts down. The flag is always cleared when Register 0xFE05[5] is set, regardless of the VDD voltage. The EEPROM_UNLOCKED flag (Register 0xFEA2[3]) indicates that the EEPROM is in the unlocked state and can be updated. The CRC_FAULT flag (Register 0xFEA2[2]) indicates that an error has occurred when downloading the EEPROM contents to the internal registers. The device shuts down and requires a PSON signal (programmed in Register 0x01 and Register 0x02) and/or the toggling of the CTRL pin (Pin 16) to restart. Flag Blanking During Soft Start Flag blanking means that when a fault condition is met, the corresponding flag is set, but there are no related actions. The following flags are always blanked during soft start: • VOUT_UV_FAULT • OT_FAULT The following flags can be programmed to be blanked during soft start, using Register 0xFE0B: • VOUT_OV_FAULT (Bit 0) • CS3_OC_FAULT (Bit 1) • IOUT_OC_FAULT (Bit 2) • IIN_OC_FAST_FAULT (Bit 3) • VIN_UV_FAULT (Bit 4) • LIGHT_LOAD (Bit 5) • DEEP_LIGHT_LOAD (Bit 5) • FLAGIN (Bit 6) • SR_RC_FAULT (Bit 7) If a flag is blanked during soft start, it is also blanked during the TON_DELAY time. Table 6. Flag Debounce Time Flag Debounce Time Register VOUT_OV_FAULT 0 μs, 1 μs, 2 μs, 8 μs 0xFE26[7:6] VOUT_UV_FAULT 0 ms, 20 ms, 40 ms, 80 ms, 160 ms, 320 ms, 640 ms, 1280 ms 0x45[2:0] IOUT_OC_FAULT 0 ms, 20 ms, 40 ms, 80 ms, 160 ms, 320 ms, 640 ms, 1280 ms 0x47[2:0] OT_FAULT 1 sec 0x50[2:0] OT_WARNING 0 ms, 100 ms 0xFE2F[2] CS3_OC_FAULT 0 ms, 10 ms, 20 ms, 200 ms 0xFE19[6:5] VIN_UV_FAULT 0 ms, 2.5 ms, 10 ms, 100 ms 0xFE29[1:0] FLAGIN 0 μs, 100 μs 0xFE12[1] SR_RC_FAULT 40 ns, 200 ns 0xFE1A[3] VDD_OV 2 μs, 500 μs 0xFE05[4] PGOOD 0 ms, 200 ms, 320 ms, 600 ms 0xFE0E[3:0] |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |