| поискавой системы для электроныых деталей |
|
ADP1052ACPZ-R7 датащи(PDF) 67 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1052ACPZ-R7 датащи(HTML) 67 Page - Analog Devices |
|
67 / 113 page ![]() Data Sheet ADP1052 Rev. B | Page 67 of 113 IOUT_CAL_GAIN The IOUT_CAL_GAIN command sets the ratio of the voltage at the current sense element to the sensed current. For devices using a fixed current sense resistor, it is typically the same value as the conductance of the resistor. The units are milliohms (mΩ). Typically, this command is used with the READ_IOUT command. RSENSE READ_IOUT IOUT_CAL_GAIN IOUT + – ADC Figure 64. Conceptual View of the Output Current Related Commands Table 38. Register 0x38—IOUT_CAL_GAIN Bits Bit Name/Function R/W Description [15:11] Exponent R/W 5-bit, twos complement, N value for linear format, X = Y × 2N, where N is in the range of −12 to 0 decimal. [10:0] Mantissa R/W 11-bit, twos complement, Y value for linear format, X = Y × 2N. VOUT_OV_FAULT_LIMIT The VOUT_OV_FAULT_LIMIT command sets the threshold value for overvoltage protection of the output voltage. Table 39. Register 0x40—VOUT_OV_FAULT_LIMIT Bits Bit Name/Function R/W Description [15:0] Mantissa R/W 16-bit, unsigned Integer Y value for linear mode format X = Y × 2N, where N is defined by the VOUT_MODE command. Note that the available OV protection limit value must be in the range of 75% to 150% of the nominal output voltage. VOUT_OV_FAULT_RESPONSE Table 40. Register 0x41—VOUT_OV_FAULT_RESPONSE Bits Bit Name/Function R/W Description [7:6] Response R/W 00 = continues operation without interruption. 01 = continues operation for the debounce time (Delay Time 1) specified by Register 0xFE26[7:6]. If the fault persists, retry the number of times specified by the retry setting of this command (Bits[5:3]). 10 = shuts down and responds according to the retry setting in Bits[5:3]. 11 = the output is disabled while the fault is present. Operation resumes and the output is enabled when the fault condition no longer exists. [5:3] Retry setting R/W 000 = restart not attempted. The output remains disabled until the fault is cleared. 001 to 110 = attempts to restart the number of times set by these bits. If the ADP1052 fails to restart in the allowed number of retries, the output is disabled and remains off until the fault is cleared. The time between the start of each attempt to restart is set by the Delay Time 2 value in Bits[2:0], together with the delay time unit specified for that particular fault. 111 = attempts to restart continuously, without limitation, until it is commanded off (by the CTRL pin, the OPERATION command, or both), VDD is removed, or another fault condition causes the device to shut down. [2:0] Delay time R/W These bits set the delay time between the start of each attempt to restart. Bit 2 Bit 1 Bit 0 Delay Time 2 (ms) 0 0 0 252 0 0 1 588 0 1 0 924 0 1 1 1260 1 0 0 1596 1 0 1 1932 1 1 0 2268 1 1 1 2604 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |