| поискавой системы для электроныых деталей |
|
CS4210 датащи(PDF) 29 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
CS4210 датащи(HTML) 29 Page - National Semiconductor (TI) |
|
29 / 102 page ![]() Revision 1.0 29 www.national.com Operational Description (Continued) 3.7.3 Isochronous Transmit Data Write Error A data write error can occur when the CS4210 attempts to write to the address indicated in a STORE_VALUE descrip- tor. This error is handled like a data read error with the exception that the event code is set to evt_data_write. The CS4210 does not begin placing the packet associated with a STORE_VALUE into the output FIFO until the STORE_VALUE operation is complete. This is to prevent the possibility of having multiple errors that cannot be prop- erly reported to system software. 3.7.4 Asynchronous Receive DMA Data Write Error When a host bus error occurs while the CS4210 is attempt- ing to write to either the request or response buffer, the CS4210 sets the corresponding ContextControl.dead and set ContextControl.event to evt_data_write. The unrecover- able error IntEvent is generated and the context’s IntEvent is not set regardless of the setting of the interrupt (i) field in the descriptor. CommandPtr.descriptorAddress points to the descriptor that contained the buffer descriptor for the memory address at which the error occurred. Any data in the input FIFO for the context is discarded. 3.7.5 Isochronous Receive Data Write Error If a data write error occurs for a context that is in packet- per-buffer mode, the CS4210 sets ContextControl.event to evt_data_write or evt_overrun and conditionally updates xferStatus of the descriptor in which the error occurred. Any remaining data in the input FIFO for the packet is dis- carded. The resCount value in a descriptor that has an error will not necessarily reflect the correct number of data bytes successfully written to memory. If a FIFO overrun occurs for a context that is in buffer-fill mode, the packet is treated as if a data length error had occurred and is ‘backed out’ of the receive buffer (xferStatus and resCount not updated) and the remainder of the packet is discarded from the input FIFO. If a host bus error occurs for a context in buffer-fill mode, the CS4210 sets ContextControl.dead and sets ContextControl.event to evt_data_write. The unre- coverable error IntEvent is generated and the context’s IntEvent is not set regardless of the setting of the interrupt (i) field in the descriptor. CommandPtr.descriptorAddress points to the descriptor that contained the buffer descriptor for the memory address at which the error occurred. Any data in the input FIFO for the context is discarded. 3.7.6 Physical Read Error When an external node does a physical access and the CS4210’s read of system memory fails, the CS4210 returns an error indication to the requester by forming a response containing a response code of resp_data_error. If the device replies with ack_busy or ack_data_error the host retries the packet. If the error was caused by a FIFO under- run, the CS4210 retries with the same response. If the error was a host bus error, the response packet is changed to resp_data_error. 3.7.7 Posted Write Error Whether to be handled by the Physical Request controller or by the Asynchronous Receive Request context, write requests to certain address ranges (see Section 3.6 "Phys- ical Requests" on page 26) may be acked with ack_complete before the data is actually written to system memory. Since the sending node has been notified that the action is complete, when the CS4210 cannot complete a posted write operation due to a host bus error the system must be notified so that software can recover. If an error occurs in writing the posted data packet, then the CS4210 sets the IntEvent.PostedWriteErr bit (BAR0+Offset 80h[8]) to indicate that an error has occurred and the write remains pending. Software can then read the source node ID and offset address from the PostedWriteAddress regis- ter and then clear IntEvent.PostedWriteErr. When software clears IntEvent.PostedWriteErr, that write is no longer pending. Although the CS4210 allows four pending writes, error reporting is through a single pair of software visible regis- ters. If multiple posted write failures have occurred, soft- ware accesses them one at a time through the PostedWriteAddress register. When software clears IntEvent.PostedWriteErr, this is a signal to the CS4210 that software has completed reading of the current contents of PostedWriteAddress and that the CS4210 can report another error by again setting IntEvent.PostedWriteErr and presenting a new set of values when software reads Post- edWriteAddress. Table 3-10 provides a map of the Posted- WriteAddress register. Refer to Section 4.4.10 "PostedWriteAddress Register" on page 64 for further reg- ister information. If the CS4210 has four pending physical writes, additional physical writes may not be posted. Instead the CS4210 returns ack_pending and only returns a complete indication when the write is actually done. Table 3-10. BAR0+Offset 38h: PostedWriteAddress Register Map 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 sourceID offsetHi offsetLo |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |