| поискавой системы для электроныых деталей |
|
CS4210 датащи(PDF) 22 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
CS4210 датащи(HTML) 22 Page - National Semiconductor (TI) |
|
22 / 102 page ![]() www.national.com 22 Revision 1.0 Operational Description (Continued) 3.3.2.5 CommandPtr Software initializes CommandPtr.descriptorAddress to con- tain the address of the first descriptor block that the CS4210 accesses when software enables the context by setting ContextControl.run. Software also initializes Com- mandPtr.Z to indicate the number of descriptors in the first descriptor block. Software only writes to this register when both ContextControl.run and ContextControl.active are zero. The CS4210’s behavior when this rule is violated is undefined. Since the CS4210 utilizes the CommandPtr reg- ister while processing a context, there is a set of guidelines by which software may safely and deterministically read CommandPtr. These guidelines are based on the Context- Control bits as listed in Table 3-8 (X = don’t care). If ContextControl.run is set and ContextControl.dead is not set, then the contents of CommandPtr are only specified if both ContextControl.active and ContextControl.wake are clear. In this instance, CommandPtr.descriptorAddress contains the address of a descriptor within the last descrip- tor block that was executed. If ContextControl.run and Con- textControl.dead are both set, then descriptorAddress points to a descriptor within the descriptor block in which an unrecoverable error occurred. Except for the case where software initializes CommandPtr, the value of Com- mandPtr.Z is undefined and Z may contain a value that is implementation dependent. The value of CommandPtr is undefined after a hardware or software reset of the CS4210. When software sets ContextControl.run to 1 and CommandPtr.Z contains an invalid value for the controller and context, or if a Z value is invalid for a fetched descriptor block in a running context, the CS4210: sets ContextCon- trol.dead to 1 and sets ContextControl.event to evt_unknown and will not process any descriptors in that context. Table 3-8. CommandPtr Read Values ContextControl Bits CommandPtr.descriptor Address Value run dead active wake 0 0 0 X A descriptor block address. Either last written or last executed. 0 0 1 X Contents unspecified. 1000 Refers to the descriptor block that contains the Z = 0 that caused the CS4210 to set active to 0. 1001 Contents unspecified. 1010 Contents unspecified. 1011 Contents unspecified. 1 1 0 X Points to the descriptor block in which a fatal error occurred. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |