| поискавой системы для электроныых деталей |
|
SC2200 датащи(PDF) 74 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
SC2200 датащи(HTML) 74 Page - National Semiconductor (TI) |
|
74 / 433 page ![]() www.national.com 74 Revision 3.0 Signal Definitions (Continued) 2.4.15 Power Management Interface Signals Signal Name Ball No. Type Description Mux EBGA TEPBGA CLK32 H29 AH8 O 32.768 KHz Output Clock --- GPWIO0 E31 AH6 I/O General Purpose Wakeup I/Os. These sig- nals each have an internal pull-up of 100 K Ω. --- GPWIO1 G28 AK5 --- GPWIO2 G29 AJ6 --- LED# D31 AL4 O LED Control. Drives an externally connected LED (on, off or a 1 Hz blink). Sleeping / Working indicator. This signal is an open- drain output. --- ONCTL# E30 AJ5 O On / Off Control. This signal indicates to the main power supply that power should be turned on. This signal is an open-drain out- put. --- PWRBTN# E29 AH5 I Power Button. Input used by the power management logic to monitor external sys- tem events, most typically a system on/off button or switch. The signal has an internal pull-up of 100 K Ω, a Schmitt-trigger input buffer and debounce protection of at least 16 ms. ACPI is non-functional when the power-up sequence does not include using the power button. If ACPI functionality is desired, the power button must be toggled. This can be done externally or internally. GPIO63 is inter- nally connected to PWRBTN#. To toggle the power button with software, GPIO63 must be programmed as an output using the normal GPIO programming protocol (see Section 5.4.1.1 "GPIO Support Registers" on page 231). GPIO63 must be pulsed low for at least 16 msec and not more than 4 sec. Asserting POR# has no effect on ACPI. If POR# is asserted and ACPI was active prior to POR#, then ACPI will remain active after POR#. Therefore, BIOS must ensure that ACPI is inactive before GPIO63 is pulsed low. --- PWRCNT1 F31 AK6 O Suspend Power Plane Control 1 and 2. Control signal asserted during power man- agement Suspend states. These signals are open-drain outputs. --- PWRCNT2 G31 AL7 O --- THRM# F28 AK4 I Thermal Event. Active low signal generated by external hardware indicating that the sys- tem temperature is too high. --- |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |