| поискавой системы для электроныых деталей |
|
BQ76PL536APAPR датащи(PDF) 43 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
BQ76PL536APAPR датащи(HTML) 43 Page - Texas Instruments |
|
43 / 74 page ![]() bq76PL536A www.ti.com SLUSAD3B – JUNE 2011 – REVISED JANUARY 2016 7.6.9 FAULT_STATUS Register (0x21) The FAULT_STATUS register provides information about the source of the FAULT signal. The host must clear each fault flag by writing a 1 to the bit that is set. The exception is bit 4, which may be written 1 or 0 as needed to implement self-test of the IC stack and wiring. Figure 32. FAULT_STATUS Register 7 6 5 4 3 2 1 0 Reserved I_FAULT FORCE POR CRC CUV COV Table 8. FAULT_STATUS Register Field Descriptions Bit Field Type Reset Description 7-6 Reserved 5 I_FAULT The device has failed an internal register consistency check. Measurement data and protection function status may not be accurate and should not be used. 0 = No internal register consistency check fault exists. 1 = The internal consistency check has failed self-test. The host should attempt to reset the device, see the RESET section. If the fault persists, the failure should be considered uncorrectable. 4 FORCE This bit asserts the FAULT signal. It can be used to verify correct operation and connectivity of the FAULT line as a part of system self-test. 0 = Deassert FAULT (default) 1 = Assert the FAULT signal 3 POR This bit indicates a power-on reset (POR) has occurred. 0 = No POR has occurred since this bit was last cleared by the host. 1 = A POR has occurred. This notifies the host that default values have been loaded to Group1 and Group2 registers, and OTP contents have been copied to Group3 registers. 2 CRC This bit indicates a garbled packet reception by the device. 0 = No errors 1 = A CRC error was detected in the last packet received. 1 CUV This bit indicates that this bq76PL536A has detected a cell undervoltage (CUV) condition. Examine CUV_FAULT to determine which cell caused the ALERT. 0 = All cells are above the CUV threshold (default). 1 = One or more cells is below the CUV threshold. 0 COV This bit indicates that this bq76PL536A has detected a cell overvoltage (COV) condition. Examine COV_FAULT to determine which cell caused the FAULT. 0 = All cells are above the COV threshold (default). 1 = One or more cells is below the COV threshold. Copyright © 2011–2016, Texas Instruments Incorporated Submit Documentation Feedback 43 Product Folder Links: bq76PL536A |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |