194 / 300 page ![]() 194 DS1085F3 CS47L35 4.16 Clocking and Sample Rates In AIF Slave Modes, it is important to ensure that SYSCLK is synchronized with the associated external LRCLK. This can be achieved by selecting an MCLK input that is derived from the same reference as the LRCLK, or can be achieved by selecting the external BCLK or LRCLK signal as a reference input to the FLL, as a source for SYSCLK. If the AIF clock domain is not synchronized with the LRCLK, clicks arising from dropped or repeated audio samples occur, due to the inherent tolerances of multiple, asynchronous, system clocks. See Section 5.4 for further details on valid clocking configurations. 4.16.7 BCLK and LRCLK Control The digital audio interfaces (AIF1–AIF3) use BCLK and LRCLK signals for synchronization. In Master Mode, these are output signals, generated by the CS47L35. In Slave Mode, these are input signals to the CS47L35. It is also possible to support mixed master/slave operation. The BCLK and LRCLK signals are controlled as shown in Fig. 4-64. See Section 4.7 for details of the associated control fields. Note that the BCLK and LRCLK signals are synchronized to SYSCLK. See Section 4.3.13 for further details. R338 (0x0152) Rate_Estimator_1 4 TRIG_ON_ STARTUP 0 Automatic Sample-Rate Detection Start-Up select 0 = Do not trigger Write Sequencer on initial detection 1 = Always trigger the Write Sequencer on sample-rate detection 3:1 LRCLK_SRC[2:0] 000 Automatic Sample-Rate Detection source 000 = AIF1LRCLK 010 = AIF2LRCLK 100 = AIF3LRCLK All other codes are reserved 0 RATE_EST_ENA 0 Automatic Sample-Rate Detection control 0 = Disabled 1 = Enabled R339 (0x0153) Rate_Estimator_2 4:0 SAMPLE_RATE_ DETECT_A[4:0] 0x00 Automatic Detection Sample Rate A (Up to four different sample rates can be configured for automatic detection.) Field coding is same as SAMPLE_RATE_n. R340 (0x0154) Rate_Estimator_3 4:0 SAMPLE_RATE_ DETECT_B[4:0] 0x00 Automatic Detection Sample Rate B (Up to four different sample rates can be configured for automatic detection.) Field coding is same as SAMPLE_RATE_n. R341 (0x0155) Rate_Estimator_4 4:0 SAMPLE_RATE_ DETECT_C[4:0] 0x00 Automatic Detection Sample Rate C (Up to four different sample rates can be configured for automatic detection.) Field coding is same as SAMPLE_RATE_n. R342 (0x0156) Rate_Estimator_5 4:0 SAMPLE_RATE_ DETECT_D[4:0] 0x00 Automatic Detection Sample Rate D (Up to four different sample rates can be configured for automatic detection.) Field coding is same as SAMPLE_RATE_n. Table 4-93. Clocking Control (Cont.) Register Address Bit Label Default Description |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |