| поискавой системы для электроныых деталей |
|
CS43L36 датащи(PDF) 18 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS43L36 датащи(HTML) 18 Page - Cirrus Logic |
|
18 / 89 page ![]() DS1081F3 18 CS43L36 3 Characteristics and Specifications Fall time of SCL and SDA Standard Mode Fast Mode Fast Mode Plus tFC — — — 300 300 120 ns ns ns Setup time for stop condition tSUSP 260 — ns SDA setup time to SCL rising tSUD 50 — ns SDA input hold time from SCL falling 4 tHDDI 0— ns Output data valid (Data/Ack) 5 Standard Mode Fast Mode Fast Mode Plus tVDDO — — — 3450 900 450 ns ns ns Bus free time between transmissions tBUF 500 — ns SDA bus capacitance Fast Mode Plus Standard Mode, Fast Mode CB — — 550 400 pF pF SCL/SDA pull-up resistance 1 VL = 1.2 V VL = 1.8 V RP 200 250 — — Switching time between RCO and PLL or SCLK 6 — 150 — µs 1.The minimum RP value (see Fig. 2-1) is determined by using the maximum VL level, the minimum sink current strength of its respective output, and the maximum low-level output voltage, VOL. The maximum RP value may be determined by how fast its associated signal must transition (e.g., the lower the RP value, the faster the I2C bus can operate for a given bus load capacitance). See the I²C bus specification referenced in Section 13. 2.All timing is relative to thresholds specified in Table 3-14, VIL and VIH for input signals, and VOL and VOH for output signals. 3.I²C control-port timing 4.Data must be held long enough to bridge the SCL transition time, tF. 5.Time from falling edge of SCL until data output is valid. 6.The switch between RCO and either SCLK or PLL occurs upon setting/clearing SCLK_PRESENT (see p. 63) and sending the I2C stop condition. An SCLK_PRESENT transition (0 to 1 or 1 to 0) starts a switch between RCO and the selected SCLK or PLL. An I2C stop condition is sent, after which a wait time of at least 150 s is required before the next I2C transaction can begin using the newly selected clock. Table 3-13. I2C Slave Port Characteristics (Cont.) Test conditions (unless specified otherwise): Fig. 2-1 shows typical connections; Inputs: GNDA = GNDL = GNDCP = 0 V; all voltages with respect to ground; min/max performance data taken with VL = 1.66–1.94 V (VL_SEL = VP) or VL = 1.1–1.3 V (VL_SEL = GNDD); inputs: Logic 0 = GNDA = 0 V, Logic 1 = VL; TA = +25°C; SDA load capacitance equal to maximum value of CB = 400 pF; minimum SDA pull-up resistance, RP(min).1 Table 3-1 describes some parameters in detail. All specifications are valid for the signals at the pins of the CS43L36 with the specified load capacitance. Parameter 2 Symbol 3 Minimum Maximum Unit tBUF tLOW Stop tHDDI tSUD tSUST tRC tHDST tHIGH tHDST tFC tSUSP Start Repeated Start Stop SDA SCL tVDDO |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |