| поискавой системы для электроныых деталей |
|
CS43L36 датащи(PDF) 48 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS43L36 датащи(HTML) 48 Page - Cirrus Logic |
|
48 / 89 page ![]() DS1081F3 48 CS43L36 5 System Applications To clear status bits set due to initiation of a path or block, the status bits must be read after the corresponding module is enabled and before normal operation begins. Otherwise, unmasking previously set status bits causes assertion of INT. As Table 4-16 indicates, interrupt sources are categorized into two groups: • Condition-based interrupt source bits are set when the condition is present and they remain set until the register is read and the condition that caused the bit to assert is no longer present. • Event-based interrupt source bits are cleared when read. In the absence of subsequent source events, reading one of these status bits returns a 0. 5 System Applications This section provides recommended procedures and instruction sequences for standard operations. 5.1 Power-Up Sequence Ex. 5-1 is the procedure for implementing HP playback from the ASP. This example sequence configures the CS43L36 for SCLK = 12.288 MHz, LRCK = 48 kHz, and TDM playback, in Slave Mode. Table 4-15. Interrupt Status Registers and Corresponding Mask Registers—0x13 Interrupt Source Status Register Interrupt Mask Register SRC Interrupt Status (Section 7.4.2) ASP RX Interrupt Status (Section 7.4.3) DAC Interrupt Status (Section 7.4.4) Detect Interrupt Status 1 (Section 7.4.5) SRC Partial Lock Interrupt Status (Section 7.4.6) VP Monitor Interrupt Status (Section 7.4.7) PLL Lock Interrupt Status (Section 7.4.8) SRC Interrupt Mask (Section 7.4.11) ASP RX Interrupt Mask (Section 7.4.12) DAC Interrupt Mask (Section 7.4.13) Detect Interrupt Mask 1 (Section 7.7.5) SRC Partial Lock Interrupt Mask (Section 7.4.14) VP Monitor Interrupt Mask (Section 7.4.15) PLL Lock Mask (Section 7.4.16) Table 4-16. Interrupt Source Types Group Status Registers Interrupt Source Type Tip sense debounce (see Section 7.2.7) TS_UNPLUG_DBNC TS_PLUG_DBNC Event Event Channel Overflow Interrupt (see Section 7.4.1 ) CHA_OVFL CHB_OVFL Event Event Serial port (see Section 7.4.2, Section 7.4.3 ) ASPRX_OVLD ASPRX_ERROR ASPRX_LATE ASPRX_EARLY 1 ASPRX_NOLRCK 1 SRC_IUNLK SRC_ILK 1.Reading this bit following an early LRCK/SM error/no LRCK returns a 1. Subsequent reads return a 0. Valid LRCK transitions or exiting the transmit overflow condition rearms the detection of the corresponding event. See Table 4-9 for details. Event Event Event Event Condition Condition Condition Global (see Section 7.4.4 ) PDN_DONE Condition Headset (see Section 7.4.5) TIP_SENSE_PLUG TIP_SENSE_UNPLUG All are events. DAC (see Section 7.4.6 ) DAC_LK Condition VP monitor (see Section 7.4.7 ) VPMON_TRIP Condition PLL (see Section 7.4.8 ) PLL_LOCK Condition Tip sense plug/unplug status (see Section 7.4.9 ) TS_UNPLUG TS_PLUG Events. Although a true event interrupt clears when read, these dynamically reflect the state of the debounced input signal. Example 5-1. Power-Up Sequence STEP TASK REGISTER/BIT FIELDS VALUE DESCRIPTION 1 Apply all relevant power supplies, then assert RST before applying SCLK and LRCK to the CS43L36. 2 Wait 2.5 ms. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |