51 / 89 page ![]() DS1081F3 51 CS43L36 5.3 Page 0x30 Read Sequence 5.3 Page 0x30 Read Sequence The following sequence is required to read from Page 0x30: 1. Power up Page 0x30 by clearing bit 7 of register 0x1102. 2. Enable Page 0x30 reads by writing the value 0x01 to register 0x1801. 3. Perform the read from Page 0x30. 5.4 PLL Clocking Data-path logic is in the MCLK domain, where SCLK is expected to be 12 or 24 MHz. For clocking scenarios where ASP_ SCLK is neither 12 nor 24 MHz, the PLL must be turned on to provide the desired internal MCLK. At startup, the system sets the SCLK bypass as default mode and switches to PLL output after it settles. PLL start-up time is a maximum of 1 ms. 5.5 VD_FILT/VL ESD Diode Note the following: • If VD_FILT is supplied externally, VL must be supplied before VD_FILT. • If the internal LDO is enabled, it generates VD_FILT from VL. • If the LDO is disabled (DIGLDO_PDN asserted) and VD_FILT is supplied externally; however, the LDO diode could be forward biased in cases where VD_FILT is supplied first. • If the LDO is disabled and VD_FILT and VL are respectively powered via separate 1.2- and 1.8-V supplies, it is recommended to have an ESD diode between VD_FILT and VL. 2 Power down the HP amplifier. Power Down Control 1. 0x1101 0xFE Reserved ASP_DAI_PDN MIXER_PDN Reserved HP_PDN Reserved PDN_ALL 1 1 1 1 1 11 0 — ASP input path is powered down Mixer is powered down — HPOUT powered down — DAC powered up 3 Power down the ASP and SRC. Power Down Control 2. 0x1102 0x8C Reserved DISCHARGE_FILT+ SRC_PDN_OVERRIDE Reserved DAC_SRC_PDNB Reserved 100 0 1 1 0 0 — FILT+ is not clamped to ground. SRC is powered down. — DAC SRC is powered down. — 4 Power down the DAC. Power Down Control 1. 0x1101 0xFF Reserved ASP_DAI_PDN MIXER_PDN Reserved HP_PDN Reserved PDN_ALL 1 1 1 1 1 11 0 — ASP input path is powered down Mixer is powered down — HPOUT powered down — DAC powered down. 5 Read PDN_DONE to confirm that the DAC is completely powered down. DAC Interrupt Status . 0x1308 0x01 Reserved PDN_DONE 0000 000 1 — Power-down done. 6 Repeat Step 5 until the PDN_DONE status bit indicates the DAC has powered down. 7 Discharge the capacitor attached to the FILT+ pin. Power Down Control 2. 0x1102 0x9C Reserved DISCHARGE_FILT+ SRC_PDN_OVERRIDE Reserved DAC_SRC_PDNB Reserved 100 1 1 1 0 0 — FILT+ is clamped to ground. SRC is powered down. — DAC SRC is powered down. — 8 If required, remove the SCLK signal. 9 If required, remove all relevant power supplies from the DAC. Example 5-2. Power-Down Sequence (Cont.) STEP TASK REGISTER/BIT FIELDS VALUE DESCRIPTION |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |