| поискавой системы для электроныых деталей |
|
ISM330DLC датащи(PDF) 35 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ISM330DLC датащи(HTML) 35 Page - STMicroelectronics |
|
35 / 116 page ![]() DocID030686 Rev 2 35/116 ISM330DLC Functionality 116 5.5 FIFO The presence of a FIFO allows consistent power saving for the system since the host processor does not need continuously poll data from the sensor, but it can wake up only when needed and burst the significant data out from the FIFO. The ISM330DLC embeds 4 kbytes data FIFO to store the following data: gyroscope accelerometer external sensors timestamp temperature Writing data in the FIFO can be configured to be triggered by the: accelerometer/gyroscope data-ready signal; in which case the ODR must be lower than or equal to both the accelerometer and gyroscope ODRs; sensor hub data-ready signal; In addition, each data can be stored at a decimated data rate compared to FIFO ODR and it is configurable by the user, setting the FIFO_CTRL3 (08h) and FIFO_CTRL4 (09h) registers. The available decimation factors are 2, 3, 4, 8, 16, 32. The programmable FIFO threshold can be set in FIFO_CTRL1 (06h) and FIFO_CTRL2 (07h) using the FTH [10:0] bits. To monitor the FIFO status, dedicated registers (FIFO_STATUS1 (3Ah), FIFO_STATUS2 (3Bh), FIFO_STATUS3 (3Ch), FIFO_STATUS4 (3Dh)) can be read to detect FIFO overrun events, FIFO full status, FIFO empty status, FIFO threshold status and the number of unread samples stored in the FIFO. To generate dedicated interrupts on the INT1 and INT2 pads of these status events, the configuration can be set in INT1_CTRL (0Dh) and INT2_CTRL (0Eh). The FIFO buffer can be configured according to five different modes: Bypass mode FIFO mode Continuous mode Continuous-to-FIFO mode Bypass-to-continuous mode Each mode is selected by the FIFO_MODE_[2:0] bits in the FIFO_CTRL5 (0Ah) register. To guarantee the correct acquisition of data during the switching into and out of FIFO mode, the first sample acquired must be discarded. 5.5.1 Bypass mode In Bypass mode (FIFO_CTRL5 (0Ah) (FIFO_MODE_[2:0] = 000), the FIFO is not operational and it remains empty. Bypass mode is also used to reset the FIFO when in FIFO mode. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |