| поискавой системы для электроныых деталей |
|
TMS320VC549 датащи(PDF) 37 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMS320VC549 датащи(HTML) 37 Page - Texas Instruments |
|
37 / 111 page ![]() TMS320C54x, TMS320LC54x, TMS320VC54x FIXED-POINT DIGITAL SIGNAL PROCESSORS SPRS039C – FEBRUARY 1996 – REVISED DECEMBER 1999 37 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 switching mode from one PLL multiplier to another (continued) Also, note that a direct switch between divide-by-two mode and divide-by-four mode is not possible. To switch between these two modes, the clock generator must first be set to PLL mode with an integer-only (non-fractional) multiplier ratio, and then set back to DIV mode in the desired divider configuration (see previous sections for details on switching between DIV and PLL modes). The following software example shows a code sequence that can be used to switch clock mode from PLL × X to PLL × 1. STM #0b, CLKMD ;switch to DIV mode TstStatu: LDM CLKMD, A AND #01b, A ;poll STATUS bit BC TstStatu, ANEQ STM #0000001111101111b, CLKMD ;switch to PLL 1 mode programmable clock generator operation immediately following reset Immediately following reset, the operating mode of the clock generator is determined only on the basis of the CLKMD1/2/3 pin state as described in Table 6. All but two of these operating modes are ’divide-by-two with external source’. Switching from divide-by-two to a PLL mode can easily be accomplished by changing the CLKMD register contents. Note that if use of the internal oscillator is desired, either the 100 or the 111 state of the CLKMD1– CLKMD3 pins must be selected at reset (as shown in Table 6) since the internal oscillator cannot be programmed through software. The following software example shows an instruction that can be used to switch from divide-by-two mode to the PLL 3 mode. STM #0010000101001111b, CLKMD considerations when using IDLE1/IDLE2/IDLE3 When using one of the IDLE instructions to reduce power requirements, proper management of the PLL is important. The clock generator consumes the least power when operating in DIV mode with the PLL disabled. Therefore, if power dissipation is a significant consideration, it is desirable to switch from PLL to DIV mode, and disable the PLL, before executing the IDLE1/IDLE2/IDLE3 instructions. This is accomplished as explained above in the section describing switching clock mode from PLL to DIV. After waking up from IDLE1/IDLE2/IDLE3, the clock generator can be reprogrammed to PLL mode as explained above in the section describing switching clock mode from DIV to PLL. Note that when the PLL is stopped during an IDLE state, and the ’54x device is restarted and the clock generator is switched back to PLL mode, the PLL lockup delay occurs in the same manner as in a normal device startup. Therefore, in this case, the lockup delay must also be accounted for, either externally or by using the PLL lockup counter timer. The following software example illustrates a code sequence that switches the clock generator from PLL 3 mode to divide-by-two mode, turns off the PLL, and enters IDLE3. After waking up from IDLE3, the clock generator is switched back from DIV mode to PLL 3 mode using a single STM instruction, with a PLLCOUNT of 64 (decimal) used for the lock timer value. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |