| поискавой системы для электроныых деталей |
|
7220 датащи(PDF) 85 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
7220 датащи(HTML) 85 Page - Renesas Technology Corp |
|
85 / 303 page ![]() 2-58 7220 Group User’s Manual FUNCTIONAL DESCRIPTION 2.8 Multi-master I2C-BUS interface (1) START condition generation method When the ESO bit of the I2C control register (address 00DA16) is “1,” execute a write instruction to the I2C status register (address 00D916) to set the MST, TRX and BB bits to “1.” A START condition will then be generated. After that, the bit counter becomes “0002” and an SCL for 1 byte is output. The START condition generating timing and BB bit set timing are different in the standard clock mode and the high-speed clock mode. Refer to “Figure 2.8.9” for the START condition generation timing diagram, and “Table 2.8.2” for the START condition/STOP condition generation timing table. (2) STOP condition generation method When the ESO bit of the I2C control register (address 00DA16) is “1,” execute a write instruction to the I2C status register (address 00D916) for setting the MST bit and the TRX bit to “1” and the BB bit to “0”. A STOP condition will then be generated. The STOP condition generation timing and the BB flag reset timing are different in the standard clock mode and the high-speed clock mode. Refer to “Figure 2.8.10” for the STOP condition generating timing diagram, and “Table 2.8.2” for the START condition/STOP condition generation timing table. 2.8.3 START condition, STOP condition generation method Fig. 2.8.9 START condition generation timing diagram I2C status register write signal Set time for BB flag Hold time Setup time SCL SDA BB flag Setup time Fig. 2.8.10 STOP condition generation timing diagram I2C status register write signal Reset time for BB flag Hold time Setup time SCL SDA BB flag Item Setup time Hold time Set/reset time for BB flag High-speed clock mode 2.5 µ s (10 cycles) 2.5 µ s (10 cycles) 1.5 µ s (6 cycles) Standard clock mode 5.0 µ s (20 cycles) 5.0 µ s (20 cycles) 3.0 µ s (12 cycles) Note: Absolute time at f = 4 MHz. The value in parentheses denotes the number of f cycles. Table 2.8.2 START condition/STOP condition generation timing table |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |