| поискавой системы для электроныых деталей |
|
AD9927BBCZ датащи(PDF) 76 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9927BBCZ датащи(HTML) 76 Page - Analog Devices |
|
76 / 100 page ![]() AD9927 Rev. 0 | Page 76 of 100 012 34 VD HD X X X X N N–1 N– 2 N–3 N–4 N– 5 N–6 N–7 N– 8 N–9 N–10 N–11 N–12 N–13 N–32 N–33 N–34 N–35 H-COUNTER RESET NOTES 1. TOGGLE POSITIONS CANNOT BE PROGRAMMED WITHIN 36 PIXELS OF PIXEL 0 LOCATION. H-COUNTER (PIXEL COUNTER) NO TOGGLE POSITIONS ALLOWED IN THIS AREA Figure 91. Toggle Position Inhibited Area—Master Mode N– 1 N 012 VD HD N– 2 N–3 N–4 NO TOGGLE POSITIONS ALLOWED IN THIS AREA N–5 N– 6 N– 7 N– 8 N– 9 N–10 N– 11 N– 12 N– 13 N– 32 N– 33 N– 34 N– 35 X X X X X X NOTES 1. TOGGLE POSITIONS CANNOT BE PROGRAMMED WITHIN 36 PIXELS OF PIXEL 0 LOCATION. H-COUNTER (PIXEL COUNTER) H-COUNTER RESET Figure 92. Toggle Position Inhibited Area—Slave Mode STANDBY MODE OPERATION The AD9927 contains three standby modes to optimize the overall power dissipation in a particular application. Bits [1:0] of Address 0x00 control the power-down state of the device: • STANDBY [1:0] = 0 = normal operation (full power) • STANDBY [1:0] = 1 = Standby1 mode • STANDBY [1:0] = 2 = Standby2 mode • STANDBY [1:0] = 3 = Standby3 mode (lowest power) Table 46 summarizes the operation of each power-down mode. The OUTCONTROL register takes priority over the Standby1 and Standby2 modes in determining the digital output states, but Standby3 mode takes priority over OUTCONTROL. Standby3 has the lowest power consumption and even shuts down the crystal oscillator circuit between CLI and CLO. Therefore, if CLI and CLO are being used with a crystal to generate the master clock, this circuit is powered down and there is no clock signal. When returning from Standby3 mode to normal operation, the timing core must be reset at least 500 μs after the STANDBY register is written to. This allows sufficient time for the crystal circuit to settle. The vertical outputs can also be programmed to hold a specific value during the Standby3 mode by using Address 0x26. This register is useful during power-up if different polarities are required by the V-driver and CCD to prevent damage when VH and VL areas are applied. The polarities for Standby1 mode and Standby2 mode are also programmable, using Address 0x25. OUTCONTROL = low also uses the same polarities programmed for Standby1 and Standby2 modes in Address 0x25. The GPO polarities are programmable using Address 0x27. Note that the GPO outputs are High-Z by default at power-up until Address 0x78 is used to select them as outputs. CLI FREQUENCY CHANGE If the input clock CLI is interrupted or changed to a different frequency, the timing core must be reset for proper operation. After the CLI clock has settled to the new frequency, or the previous frequency is resumed, write 0 and then 1 to the TGCORE_RSTB register (Address 0x14). This guarantees that the timing core operates properly. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |