| поискавой системы для электроныых деталей |
|
AD9927BBCZ датащи(PDF) 74 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9927BBCZ датащи(HTML) 74 Page - Analog Devices |
|
74 / 100 page ![]() AD9927 Rev. 0 | Page 74 of 100 Table 45. Power-Up Register Write Sequence Address Data Description 0x10 0x01 Reset all registers to default values 0x26 User- defined Standby3 vertical output polarities 0x20 to 0xFFF User- defined Horizontal, vertical, shutter timing 0xD8 0x888 Configure start-up register 0x00 0x04 Power-up the AFE, enables OB clamp 0x15 0x01 Starts CLO oscillator (if using crystal) 0x14 0x01 Starts internal timing core 0x20 0x01 Configure for master mode 0x11 0x01 Enable all outputs after SYNC 0x1C 0xFF8000 Configure sensor gate signals 0x13 0x4XX1 SWSYNC (if using software SYNC) Using the SWSYNC Register If an external SYNC pulse is not available, it is possible to generate an internal SYNC in the AD9927 by writing 1 to the SWSYNC register (Address 0x13, Bit [14]). If the software SYNC option is used, the SYNC input (Pin D3) should be low (VSS) during power-up. The SYNCENABLE register (Address 0x13, Bit [0]) should be set high. SYNC During Master Mode Operation The hardware SYNC input can be used anytime during operation to synchronize the AD9927 counters with external timing, as shown in Figure 88. The operation of the digital outputs can be suspended during the SYNC operation by setting the SYNCSUSPEND register (Address 0x13, Bit [2]) to 1. If SYNCSUSPEND = 1, the polarities of the outputs are held at the same state as OUTCONTROL = low, as shown in Table 46. Power-Up and Synchronization in Slave Mode The power-up procedure for slave mode operation is the same as the procedure for master mode operation with two exceptions: • Eliminate Step 8. Do not write the part into master mode. • No SYNC pulse is required in slave mode. Substitute Step 10 with starting the external VD and HD signals. This synchronizes the part, allows the register updates, and starts the timing operation. When the AD9927 is used in slave mode, the VD/HD inputs are used to synchronize the internal counters. After a falling edge of VD, there is a latency of 36 master clock CLI edges after the falling edge of HD until the internal H-counter is reset. The reset operation is shown in Figure 89. Additional Restrictions in Slave Mode When operating in slave mode, the following restrictions should be noted: • The HD falling edge should be located in the same CLI clock cycle as the VD falling edge, or later than the VD falling edge. The HD falling edge should not be located within five cycles prior to the VD falling edge. • If possible, all start-up serial writes should be performed with VD and HD disabled. This prevents unknown behavior caused by partial updating of registers before all information is loaded. VD HD SUSPEND SYNC H1 TO H4, RG, XV1 TO XV24, VSG, SUBCK NOTES 1. THE SYNC RISING EDGE RESETS VD/HD AND COUNTERS TO 0. 2. SYNC POLARITY IS PROGRAMMABLE USING SYNCPOL REGISTER (ADDR 0x13). 3. DURING SYNC LOW, ALL INTERNAL COUNTERS ARE RESET AND VD/HD CAN BE SUSPENDED USING THE SYNCSUSPEND REGISTER (ADDR 0x13). 4. IF SYNCSUSPEND = 1, VERTICAL CLOCKS, H1 TO H4, AND RG ARE HELD AT THE SAME POLARITY SPECIFIED BY OUTCONTROL = LOW. 5. IF SYNCSUSPEND = 0, ALL CLOCK OUTPUTS CONTINUE TO OPERATE NORMALLY UNTIL THE SYNC RESET EDGE. Figure 88. SYNC Timing to Synchronize the AD9927 with External Timing |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |