| поискавой системы для электроныых деталей |
|
DA16200 датащи(PDF) 73 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
DA16200 датащи(HTML) 73 Page - Renesas Technology Corp |
|
73 / 154 page ![]() DA16200 Ultra Low Power Wi-Fi SoC Datasheet Revision 3.6 04-Jan-2023 CFR0011-120-00 73 of 153 © 2023 Renesas Electronics 9.10.3 Baud Rate The UART clock frequency (FUARTCLK) is fixed at 80 MHz. The Baud Rate Divisor can be calculated as (FUARTCLK / (16 x Baud Rate)). The Baud Rate Divisor is comprised of the integer part (UART_INTBRDIV) and fractional part (UART_FRABRDIV). The maximum baud rate of DA16200 UART is 2.5 MBaud. The example below shows how to calculate the divisor value. If the required baud rate is 921600 with 80 MHz FUARTCLK, the Baud Rate Divisor becomes: (8 x 107) / (16 x 921600) = 5.425. This means that the integer value is 5 and the fractional value is 0.425. Then, the fraction part becomes integer ((0.425 x 64) + 0.5) = 27. Then, the generated baud rate divider is 5 + 27/64 = 5.422. Finally, the generated baud rate becomes (8 x 107) / (16 x 5.422) = 922169. And the error between the required baud rate and the generated baud rate is: (922169 – 921600) / 921600 x100 = 0.062 % 9.10.4 Hardware Flow Control The hardware flow control feature is fully selectable, and serial data flow is controlled by using nUARTRTS output and nUARTCTS input signals. Figure 53 shows how two different UARTs can communicate using hardware flow control. Figure 53: UART Hardware Flow Control When RTS flow control is enabled, nUARTRTS signal is asserted until the receive FIFO is filled up to programmed level. When CTS flow control is enabled, the transmitter can transmit the data when the nUARTCTS signal is asserted. CTSEn (CTS enable) and RTSEn (RTS enable) bits are determined by 14th (RTS) and 15th bit (CTS) of UARTCR register. Table 54: Control Bits to Enable and Disable Hardware Flow Control CTSEn RTSEn Description 1 1 Both RTS and CTS flow control are enabled 1 0 Only CTS flow control is enabled 0 1 Only RTS flow control is enabled 0 0 Both RTS and CTS flow control are disabled |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |