53 / 154 page ![]() DA16200 Ultra Low Power Wi-Fi SoC Datasheet Revision 3.6 04-Jan-2023 CFR0011-120-00 53 of 153 © 2023 Renesas Electronics 9.3 SPI Slave The SPI slave interface is a half-duplex connection for an external host to control the DA16200. The range of the SPI clock speed is based on the internal bus clock speed and can be calculated using: spi clock = system clock/N where N is an integer divider such as 1,2,3,4,5,6,... The SPI slave supports both the Burst mode and Non-burst mode. In the Burst mode, SPI_CSB remains active from the start to the end of communication. In the Non-burst mode, SPI_CSB remains active at every eight bits. SPI Signals Address Decoder Command Decoder Data Decoder APB bus Controller Figure 26: SPI Slave Block Diagram Communication protocols of the SPI slave interface use either 4-byte or 8-byte control signals. Between the two available communication protocols, the CPU chooses one before initiating the control. Figure 27 and Figure 28 shows the 8-byte and 4-byte control types. SPI_CSB SPI_CLK SPI_MOSI A [ 31 : 24 ] A [ 7 : 0 ] A [ 15 : 8 ] A [ 23 : 16 ] C [ 7 : 0 ] L [ 23 : 16 ] L [ 15 : 8 ] L [ 7 : 0 ] D [ 7 : 0 ] D [ 15 : 8 ] D [ 23 : 16 ] D [ 31 : 24 ] Figure 27: 8-byte Control Type SPI_CSB SPI_CLK SPI_MOSI A [ 15 : 8 ] L [ 7 : 0 ] C [ 7 : 0 ] A [ 7 : 0 ] D [ 7 : 0 ] D [ 15 : 8 ] D [ 23 : 16 ] D [ 31 : 24 ] Figure 28: 4-byte Control Type The 8-byte control type uses a 4-byte address, 1-byte control, and 3-byte length. The 4-byte address displays the address of registers subject to internal access. The 1-byte control is for communication control and 3-byte length shows the length of data subject to continuous access in bytes. Hence, when the 8-byte control type is applied, the maximal length of data subject to continuous access is 16 MB. The 4-byte control type uses a 2-byte address, 1-byte control, and 1-byte length. The 2-byte address displays the address of registers subject to internal access. The 1-byte control is for communication control and 1-byte length shows the length of data subject to continuous access in bytes. Since the 32-bit address map is used internally, the 2-byte address is not enough to express everything. Thus, the upper 2-byte base address is designated, and then the lower 2-byte address is used. Table 36 and Table 37 shows the meaning of each bit in the 1-byte control in the 8-byte control type and the 4-byte control type, respectively. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |