113 / 132 page ![]() VT8231 Preliminary Revision 0.8 October 29, 1999 -107- Hardware Monitor I/O Space Registers 7HFKQRORJLHV ,QF :H &RQQHFW :H &RQQHFW Offset 47 –Hardware Monitor Fan Configuration.........RW 7-6 Fan 2 RPM Control 00 Divide by 1 01 Divide by 2 ............................................default 10 Divide by 4 11 Divide by 8 5-4 Fan 1 RPM Control 00 Divide by 1 01 Divide by 2 ............................................default 10 Divide by 4 11 Divide by 8 3-0 Reserved ........................................ always reads 0 Offset 49 –Hardware Monitor Temp Low Order Value RW 7-6 TSENS3 Value Low-Order Bits Upper 8 bits are stored in offset 1Fh 5-4 TSENS2 Value Low-Order Bits Upper 8 bits are stored in offset 21h 3 Over Temperature Active Low for PMU to Control Stop Clock 0 Disable ...................................................default 1Enable 2 Chassis Active Low Output 20 msec 0 Disable ...................................................default 1Enable 1 Interrupt Active High Output 0 Disable ...................................................default 1Enable 0 Reserved ........................................ always reads 0 Offset 4B –Temperature Interrupt Configuration ........ RW 7-6 TSENS1 Value Low-Order Bits ..................def = 00 Upper 8 bits are stored in offset 20h 5-4 TSENS3 Hot Temp Interrupt Mode ...........def = 01 3-2 TSENS2 Hot Temp Interrupt Mode ...........def = 01 1-0 TSENS1 Hot Temp Interrupt Mode ...........def = 01 The following applies to each of the above 3 fields 00 Default Interrupt Mode. An interrupt occurs if the temperature goes above the hot limit. The interrupt will be cleared once the status register is read, but will be generated again when the next conversion is completed. Interrupts will continue to be generated until the temperature goes below the hysteresis limit. 01 One-Time Interrupt Mode. An interrupt is generated if the temperrature goes above the hot limit. The interrupt will be cleared when the status register is read. Another interrupt will not be generated until the temperature first drops below the hysteresis limit............. default 10 Comparator mode. An interrupt occurs if the temperature goes above the hot limit. This interrupt remains active until the temperature goes below the hot limit (i.e., no hysteresis). 11 Default Interrupt Mode (same as 00) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |