| поискавой системы для электроныых деталей |
|
FXOS8700CQ датащи(PDF) 27 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
FXOS8700CQ датащи(HTML) 27 Page - Freescale Semiconductor, Inc |
|
27 / 86 page ![]() Sensors Freescale Semiconductor, Inc. 27 9 Registers by Functional Blocks 9.1 Device configuration 9.1.1 STATUS (0x00) register The STATUS register aliases allow for the contiguous burst read of both status and current acceleration sample/FIFO data using the auto incrementing mechanism in both 8 and 14-bit modes. 9.1.2 DR_STATUS (0x00) register Data-Ready Status when STATUS = 0x00 This STATUS register provides the acquisition status information on a per-sample basis, and reflects real-time updates to the OUTX, OUTY, and OUTZ registers. When the FIFO subsystem data output register driver is disabled (F_SETUP[f_mode] = 0b00), this register indicates the real- time status information of the X, Y, and Z sample data. DR_STATUS or F_STATUS 00000000 Figure 10. STATUS register Table 15. STATUS Description Field Description F_SETUP[f_mode] = 0b00 register 0x00 → DR_STATUS F_SETUP[f_mode] > 0b00 register 0x00 → F_STATUS zyxow zow yor xor zyxdr zdr ydr xdr 00000000 Figure 11. DR_STATUS register Table 16. DR_STATUS description Field Description zyxow zyxow is set to 1 whenever new data is acquired before completing the retrieval of the previous set. This event occurs when the content of at least one acceleration data register (i.e. OUTX, OUTY, and OUTZ) has been overwritten. zyxow is cleared when the high-bytes of the acceleration data (OUTX_MSB, OUTY_MSB, and OUTZ_MSB) are read. X, Y, Z-axis data overwrite. 0: No data overwrite has occurred 1: Previous X, Y, Z data was overwritten by new X, Y, Z data before it was completely read zow zow is set to 1 whenever a new Z-axis acquisition is completed before the retrieval of the previous data. When this occurs the previous data is overwritten. zow is cleared anytime OUTZ_MSB register is read. Z-axis data overwrite. 0: No data overwrite has occurred 1: Previous Z-axis data was overwritten by new Z-axis data before it was read yow yow is set to 1 whenever a new Y-axis acquisition is completed before the retrieval of the previous data. When this occurs the previous data is overwritten. yow is cleared anytime OUTY_MSB register is read. Y-axis data overwrite. 0: No data overwrite has occurred 1: Previous Y-axis data was overwritten by new Y-axis data before it was read |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |