| поискавой системы для электроныых деталей |
|
M16C/1N датащи(PDF) 104 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
M16C/1N датащи(HTML) 104 Page - Renesas Technology Corp |
|
104 / 238 page ![]() Rev.1.00 Oct 20, 2004 page 92 of 222 M16C/1N Group 12. Timers REJ09B0007-0100Z (Note 1) (Note 1) (Note 1) b7 b0 Prescaler Z Symbol PREZ Address 008516 When reset FF16 RW RW RW RW RW Function Values that can be set Timer mode Internal count source or Timer Y underflow is counted 0016 to FF16 Programmable waveform generation mode Internal count source or Timer Y underflow is counted 0016 to FF16 Programmable one-shot generation mode Internal count source or Timer Y underflow is counted 0016 to FF16 Programmable wait one-shot generation mode Internal count source or Timer Y underflow is counted 0016 to FF16 Note 1: When using the waveform extend function, set the value "0016" for the Prescaler Z. b7 b0 Timer Z Primary Symbol TZPR Address 008716 When reset FF16 RW RW RW RW RW Function Values that can be set 0016 to FF16 0016 to FF16 Note 1: Each value of Timer Z Primary and Timer Z Secondary is reloaded to the Timer Z alternately for counting. b7 b0 Timer Z Secondary Symbol TZSC Address 008616 When reset FF16 RW WO WO Function Values that can be set Timer mode Invalid Programmable waveform generation mode Underflow of Prescaler Z is counted (Note 1) 0016 to FF16 Programmable one-shot generation mode Invalid Programmable wait one-shot generation mode Underflow of Prescaler Z is counted (One-shot width is counted) 0016 to FF16 0016 to FF16 0016 to FF16 Note 1: Each value of Timer Z Primary and Timer Z Secondary is reloaded to the Timer Z alternately for counting. Note 2: The count value can be read out by reading the Timer Z Primary even when the secondary period is being counted. Timer mode Underflow of Prescaler Z is counted Programmable waveform generation mode Underflow of Prescaler Z is counted (Note 1) Programmable one-shot generation mode Underflow of Prescaler Z is counted (One-shot width is counted) Programmable wait one-shot generation mode Underflow of Prescaler Z is counted (Wait period is counted) (Note 2) Figure 12.22 Timer Z-related registers (2) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |