M16C/1N датащи(PDF) 49 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
M16C/1N датащи(HTML) 49 Page - Renesas Technology Corp |
|
49 / 238 page ![]() Rev.1.00 Oct 20, 2004 page 37 of 222 M16C/1N Group 6. Clock Generation Circuit REJ09B0007-0100Z CM20 CM21 CM22 CM23 Main clock switch bit Oscillation stop detection interrupt enable bit Oscillation stop detection bit Clock monitor bit (Note 5) Reserved bit Set to "0" Note 1: In case of writing to this register, set bit 0 of the protect register (address 000A16) to "1". Note 2: Set to "0" before stopping the oscillation of the main clock (XIN-XOUT). (stop mode, low power dissipation mode, on-chip oscillation mode) An oscillation stop is detected if the oscillation of the main clock (XIN-XOUT) is stopped when the following two conditions are satisfied: (1) the oscillation stop detection function is valid and (2) CM21=1. Note 3: Valid when CM20=1. Note 4: CM22 bit switches to "1" automatically if an oscillation stop is detected when both CM20 bit and CM 21 bit are "1". CM22 bit cannot be cleared when CM23=1. Note 5: This bit is valid when both CM20 bit is "1". Use this bit for the purpose of confirming XIN operation for oscillation stop detection interrupt execution. b7 b6 b5 b4 b3 b2 b1 b0 0 00 0 0 : XIN oscillating normally 1 : XIN stopping abnormally 0 : Select XIN clock 1 : Select on-chip oscillator (Note 4) 0 : Disabled 1 : Enabled (Note 3) 0 : The function is invalid 1 : The function is valid (Note 2) Oscillation stop detection register (Note 1) Symbol CM2 Address 000C16 When reset 0416 RW RW RW RW RO RW Function Bit name Bit symbol Figure 6.11 Oscillation stop detection register fMAIN CM22 CM21 Oscillation stop detection interrupt generating circuit Charge/discharge circuit On-chip oscillator To the CPU Watchdog timer interrupt Main clock Main clock switch control To the main clock division circuit Compulsory discharge when CM20=0 Pulse generation circuit for clock edge detection and charge/ discharge control CM14 (Note 1) #: When XIN is supplied, this repeats charge and discharge with pulses by XIN edge detection. When XIN is not supplied, this continues charging. When the charge exceeds a certain level, it regards the oscillation as stopped. Note 1: As for the fMAIN, see Figure 6.1 clock generating circuit. Figure 6.10 Oscillation stop detection circuit |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |