| поискавой системы для электроныых деталей |
|
LTC6952 датащи(PDF) 24 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTC6952 датащи(HTML) 24 Page - Analog Devices |
|
24 / 80 page ![]() LTC6952 24 6952f For more information www.analog.com Preliminary Technical Data Advance Product Information Subject to Change Rev PrA Table 13. Synchronization (SRQMD = 0) Output Behavior vs Device Settings for with PLL Enabled (PDPLL = 0) SRQENx PARSYNC MODEx Internal Divider Sync to Other Dividers Internal Divider Sync to RDIV Internal Divider Start Latency from SYNC Signal Falling Edge (DDELx = 0) Output Behavior 0 N/A 0 No No N/A Free Running 1, 2, or 3 Muted 1 0 0 Yes Yes ~45µs + R/fREF + 8/fVCO Mute on SYNC High, Run on SYNC Low 1 or 3 Muted 2 SYNC Signal Pass Through 1 0 Yes Yes (x + R)/fREF + 8/fVCO* Mute on SYNC High, Run on SYNC Low 1 or 3 Muted 2 SYNC Signal Pass Through * Latency depends on the duration of the SYNC pulse, specifically x = floor (tSYNC × fREF - 1) mod R. All outputs will be synchronized correctly regardless of x Table 14. Synchronization (SRQMD = 0) Output Behavior vs Device Settings for with PLL Disabled (PDPLL = 1) SRQENx PARSYNC MODEx Internal Divider Sync to Other Dividers Internal Divider Sync to RDIV Internal Divider Start Latency from SYNC Signal Falling Edge (DDELx = 0) Output Behavior 0 N/A 0 No No N/A Free Running 1, 2, or 3 Muted 1 0 0 Yes No ~45µs + 7/fVCO Mute on SYNC High, Run on SYNC Low 1 or 3 Muted 2 SYNC Signal Pass Through 1 0 Yes No 7/fVCO Mute on SYNC High, Run on SYNC Low 1 or 3 Muted 2 SYNC Signal Pass Through OPERATION The LTC6952 supports three different methods of SYSREF generation as described in the JESD204B specification: • Free Running • Gated On/Off by a SYSREF Request Signal • One, Two, Four, or Eight SYSREF Pulses After the Rising Edge of a SYSREF Request Signal These modes are defined by each output’s individually pro- grammableMODExbits.InordertogenerateSYSREFpulses, bit SRQMD must be set to “1” as shown in Table 12, and MPx must be greater than 0. SYSREF requests (SYSREQ) are applied on the EZS_SRQ± pins or by setting the SSRQ bit to “1” (unless PARSYNC = 1). Table 15 describes the output behavior in SYSREF generation mode. Bits SYSCT[1:0] can be found in register h0B. Note that synchronization MUST be completed prior to SYSREF generation as described in the Synchronization Overview. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |