| поискавой системы для электроныых деталей |
|
LTC6952 датащи(PDF) 71 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTC6952 датащи(HTML) 71 Page - Analog Devices |
|
71 / 80 page ![]() LTC6952 71 6952f For more information www.analog.com Preliminary Technical Data Advance Product Information Subject to Change Rev PrA APPLICATIONS INFORMATION USING THE LTC6952 TO DRIVE AC COUPLED SYSREF INPUTS IN CONTINUOUS OR GATED MODE Some converters cannot accept a 2.3V common mode CML signal. In this situation, the SYSREF must be AC coupled. AC coupling complicates the usage of SYSREF since it is generally not continuously operational, lead- ing to long settling time requirements before a SYSREF is requested. However, AC coupling on SYSREF can be accomplished by using the connections shown in Figure 49 for continuous or gated SYSREF pulses (MODEx = 0 or 1). Note that some receiver devices have the 100Ω termination resistor internal to the part, in which case the external 100Ω resistor is unnecessary for continuous or gated SYSREFs. Continuous or Gated SYSREFs (MODEx = 0 or 1) 1. Enable the LTC6952 SYSREF output drivers by setting PDx = 0 and set SRQMD = 1. 2. If gated SYSREFs (MODEx = 1) are being used, set SSRQ or the EZS_SRQ inputs to “1”. 3. Wait for a settling period of at least tsettleC. 4. Set the receiver device to accept SYSREFs. 5. After the SYSREFs have been accepted by the receiver device, set the device to stop accepting SYSREFs. 6. If gated SYSREFs (MODEx = 1) are being used, set SSRQ or the EZS_SRQ inputs to “0”. 7. Disable the LTC6952 SYSREF output drivers by setting PDx = 2 and set SRQMD = 0. USING THE LTC6952 TO DRIVE AC COUPLED SYSREF INPUTS IN PULSED MODE If AC coupling is required for pulsed SYSREF applications (MODEx = 3), the connections shown in Figure 50 can be used. Note that some receiver devices have the 100Ω ter- mination resistor internal to the part. In this situation, the use of AC coupled, pulsed SYSREFs is not recommended. RDIFF/2 RDIFF/2 RCM 100Ω CAC CAC R1 R2 ADC, DAC, or FPGA SYSREF+ SYSREF– VCM OUTx+ OUTx– LTC6952 Z0 Z0 VDD 6952 F50 100Ω CAC CAC RDIFF/2 RDIFF/2 RCM 6952 F49 OUTx+ OUTx– LTC6952 Z0 Z0 ADC, DAC, or FPGA SYSREF+ SYSREF– VCM Settling time for continuous or gated SYSREF connections is determined by the AC coupling capacitors (CAC), and both the differential and common mode input resistances of the receiver device (RDIFF and RCM): tsettleC ≅ 10 • (2RCM + RDIFF/2) • CAC Use the following procedure to achieve correct JESD204B SYSREF behavior for AC coupled continuous or gated SYSREFs. These methods assume that the SYSREF outputs have already been synchronized and that the SYSREF output drivers have been disabled for power savings (PDx = 2). Figure 49. OUTx CML AC Coupled Connections to SYSREF Inputs for Continuous or Gated Mode Operation Figure 50. OUTx CML AC Coupled Connections to SYSREF Inputs for Pulsed Mode Operation |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |