40 / 182 page ![]() 40 8048B–AVR–03/09 ATtiny43U As current consumption goes below I MS (see Figure 8-5) the converter goes from Active Regu- lated Mode to Active Low Current Mode. After this, the more the load current is decreased the longer the discharge time of the output capacitor, i.e. the time when the converter is not switch- ing, will be. Similarly, the charge time, i.e. the time when the converter is switching, will be shorter. Note that in Active Low Current Mode only the last part of the rising/switching slope is changed. Charge time can be minimised by forcing the device into Full Duty Cycle mode of operation (see “Full Duty Cycle” on page 41). When load current increases above I MS the converter goes back to Active Regulated Mode. 8.3 Output Voltage versus Load Current The output voltage of the boost converter depends on the amount of load and method of duty cycle control. In Active Mode the boost converter operates in one of two sub-modes called (Active) Regulated Mode and (Active) Low Current Mode. In Regulated Mode the emphasis is on maintaining a sta- ble output voltage, while in Low Current Mode the emphasis is on minimising current consumption. The converter always enters Active Regulated Mode at first and switches to Low Current Mode automatically when required but it is possible to design the application such that the converter always stays in Active Regulated Mode. The boost converter goes from Active Regulated Mode to Active Low Current Mode when the duty cycle reaches its minimum and the output voltage reaches its maximum. At this point the converter stops switching and the output voltage starts to fall. The converter starts switching again when the output voltage has fallen to the low limit defined for Low Current Mode. If load current increases sufficiently the converter will go back from Active Low Current Mode to Active Regulated Mode. See Figure 21-1 on page 165. The boost converter goes back to Start Mode if output voltage drops below V BOOST, and starts over from Stop Mode if input voltage drops below V STOP, or when instructed by firmware to do so. 8.3.1 Active Regulated Mode This is the default method of operation in Active Mode. The converter will remain in this mode provided that load current is sufficiently high. See “Active Low Current Mode” on page 41. In this mode of operation the output voltage is constantly regulated. This means a stable output voltage with a low amplitude, high frequency ripple superimposed. See Figure 8-6 and Table 20- 7 on page 159. The firmware can instruct the converter to leave this mode and enter Stop Mode. See “Software Control of Boost Converter” on page 42. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |