113 / 218 page ![]() 113 Parallel Port (Logical Device 4) www.national.com In SPP Compatible mode, the parallel port does not write data to the output signals. Bit 5 of the CTR register has no effect in this state. If data is written (WR goes low), the data is sent to the output signals PD7-0. If a read cycle is initiated (RD goes low), the system reads the contents of the output latch, and not data from the PD7-0 output signals. In SPP Extended mode, the parallel port can read and write external data via PD7-0. In this mode, bit 5 sets the direction for data in or data out, while read or write cycles are possi- ble in both settings of bit 5. If bit 5 of CTR is cleared to 0, data is written to the output signals PD7-0 when a write cycle occurs. (if a read cycle oc- curs in this setting, the system reads the output latch, not data from PD7-0). If bit 5 of CTR is set to 1, data is read from the output signals PD7-0 when a read cycle occurs. A write cycle in this setting only writes to the output latch, not to the output signals PD7- 0. The reset value of this register is 0. FIGURE 6-1. DTR Register Bitmap (SPP Mode) SPP Extended 0 1 0 Data written to PD7-0. 1 1 0 Data written is latched 00 1 Data read from output latch. 1 0 1 Data read from PD7-0. Mode Bit 5 of CTR RD WR Result 76543210 Reset Required 0 0 0 0 0 0 0 0 SPP Data Register (DTR) Offset 00h D2 D4 D5 D6 D7 D0 D1 D3 Data Bits 6.2.3 Status Register (STR), Offset 01h This read-only register holds status information. A system write operation to STR is an invalid operation that has no ef- fect on the parallel port. FIGURE 6-2. STR Register Bitmap (SPP Mode) Bit 0 - Time-Out Status In EPP modes only, this is the time-out status bit. In all other modes this bit has no function and has the con- stant value 1. This bit is cleared when an EPP mode is enabled. Thereafter, this bit is set to 1 when a time-out occurs in an EPP cycle and is cleared when STR is read. In EPP modes: 0 - An EPP mode is set. No time-out occurred since STR was last read. 1 - Time-out occurred on EPP cycle (minimum of 10 µsec). (Default) Bit 1 - Reserved This bit is reserved and is always 1. Bit 2 - IRQ Status In all modes except SPP Extended, this bit is always 1. In SPP Extended mode this bit is the IRQ status bit. It re- mains high unless the interrupt request is enabled (bit 4 of CTR set high). This bit is high except when latched low when the ACK signal makes a low to high transition, indi- cating a character is now being transferred to the printer. Reading this bit resets it to 1. 0 - Interrupt requested in SPP Extended mode. 1 - No interrupt requested. (Default) Bit 3 - ERR Status This bit reflects the current state of the printer error sig- nal, ERR. The printer sets this bit low when there is a printer error. 0 - Printer error. 1 - No printer error. Bit 4 - SLCT Status This bit reflects the current state of the printer select sig- nal, SLCT. The printer sets this bit high when it is on-line and selected. 0 - No printer selected. 1 - Printer selected and online. 76543210 Reset Required 1 1 1 1 1 1 1 1 SPP Status Register (STR) Offset 01h IRQ Status SLCT Status PE Status ACK Status Printer Status Time-Out Status Reserved ERR Status |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |