| поискавой системы для электроныых деталей |
|
TMS570LS1114 датащи(PDF) 98 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMS570LS1114 датащи(HTML) 98 Page - Texas Instruments |
|
98 / 169 page ![]() TMS570LS1114 SPNS188B – OCTOBER 2012 – REVISED FEBRUARY 2015 www.ti.com 6.18 Error Signaling Module The Error Signaling Module (ESM) manages the various error conditions on the RM4x microcontroller. The error condition is handled based on a fixed severity level assigned to it. Any severe error condition can be configured to drive a low level on a dedicated device terminal called nERROR. This can be used as an indicator to an external monitor circuit to put the system into a safe state. 6.18.1 Features The features of the Error Signaling Module are: • 128 interrupt/error channels are supported, divided into 3 different groups – 64 channels with maskable interrupt and configurable error pin behavior – 32 error channels with non-maskable interrupt and predefined error pin behavior – 32 channels with predefined error pin behavior only • Error pin to signal severe device failure • Configurable timebase for error signal • Error forcing capability 6.18.2 ESM Channel Assignments The Error Signaling Module (ESM) integrates all the device error conditions and groups them in the order of severity. Group1 is used for errors of the lowest severity while Group3 is used for errors of the highest severity. The device response to each error is determined by the severity group it is connected to. Table 6-35 shows the channel assignment for each group. Table 6-34. ESM Groups ERROR GROUP INTERRUPT CHARACTERISTICS INFLUENCE ON ERROR PIN Group1 maskable, low or high priority configurable Group2 non-maskable, high priority fixed Group3 no interrupt generated fixed Table 6-35. ESM Channel Assignments ERROR Condition Group Channels Reserved Group1 0 MibADC2 - RAM parity error Group1 1 DMA - MPU configuration violation Group1 2 DMA - control packet RAM parity error Group1 3 Reserved Group1 4 DMA - error on DMA read access, imprecise error Group1 5 FMC - correctable ECC error: bus1 and bus2 interfaces Group1 6 (does not include accesses to Bank 7) N2HET1 - RAM parity error Group1 7 HTU1/HTU2 - dual-control packet RAM parity error Group1 8 HTU1/HTU2 - MPU configuration violation Group1 9 PLL1 - Slip Group1 10 Clock Monitor - oscillator fail Group1 11 Reserved Group1 12 DMA - error on DMA write access, imprecise error Group1 13 Reserved Group1 14 VIM RAM - parity error Group1 15 Reserved Group1 16 MibSPI1 - RAM parity error Group1 17 MibSPI3 - RAM parity error Group1 18 98 System Information and Electrical Specifications Copyright © 2012–2015, Texas Instruments Incorporated Submit Documentation Feedback Product Folder Links: TMS570LS1114 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |