| поискавой системы для электроныых деталей |
|
ACE9050 датащи(PDF) 37 Page - Mitel Networks Corporation |
|
|
|||||||||||||||||||||||||||||
ACE9050 датащи(HTML) 37 Page - Mitel Networks Corporation |
|
37 / 52 page ![]() ACE9050 37 VC_CCN Mode ENWS Description Data reframe = disabled IRQ-BI-SAT = Busy/Idle Busy/Idle bits extracted Data reframe = enabled IRQ-BI-SAT = Not Valid Busy/Idle bits not extracted Data reframe = disabled IRQ-BI-SAT = SAT update Data reframe = enabled IRQ-BI-SAT = SAT update Control channel syncronised Control channel unsynchronised Voice channel Voice channel 0 0 1 1 0 1 0 1 Table 78 Control Channel When on a Control channel the software must decide when to switch between the synchronised and unsynchronised modes. The Modem does not give any direct indication that bit synchronisation has been achieved; however, the IRQ-WS provides indication that a Barker code has been detected. The system designer can look for the IRQ-WS being generated regularly in a suitable time window corresponding to the frame time, RSSI levels and squelch levels, before determining the Modem is in synchronisation. Once the software has determined that the Modem is in synchronisation the ENWS bit must to be set to zero. The Word Sync Detector will then remove the Busy/Idle bits from the incoming data stream and not re-synchronise on Barker codes. The software must disable ENWS before the first Busy/Idle bit occurs after the Barker Code in the control channel frame. The time for this is 1ms on AMPS or 1·25ms on TACS systems. The software does not then have to re-enable ENWS unless synchronisation is lost. As the number of bits in a frame is not divisible by eight the Word Sync Detector circuit uses frame counters to realign the data on subsequent frames instead of Barker codes. This ensures spurious Barker codes occurring in the data do not upset the synchronisation of the Modem. Due to this action Barker codes will appear distorted when read in the RXD registers. The dotting and Barker code will appear as the following three consecutive bytes: AAH, B8H and 12H. Once in synchronisation, the software must ensure that the IRQ-WS still occur within the time window set up. If a number of IRQ-WS are missed, the software must assume the Modem has become unsynchronised and take appropriate action. It is up to the system designer to decide on the threshold for the number of IRQ-WS dropped, or any other type of software averaging . Table 79 shows a typical sequence for locking onto data when on a Control channel. Voice Channel Data is not a continuous stream on a Voice channel, as on a Control channel. The data sequence also does not contain Busy/ Idle bits. The software designer has to determine when valid data is present on the voice channel. The IRQ-WS interrupt timinq cannot be used for this purpose, as the data stream is not continuous. Also IRQ-WS interrupts will occur sporadically, even when no data is present, due to the probability of an incoming signal beinq decoded as a valid Barker code. The voice channel data sequence begins with a long dottinq sequence. The software can monitor the data present in the RXD registers, and when these reliably yield a pattern of AAH or 55H it can be assumed a data sequence is beinq transmitted. The software should then ensure an IRQ-WS occurs to indicate valid data is beinq received. Other system parameters such as RSSI, RX audio level and SAT can also be measured by the software. ENWS may be left enabled, or disabled after synchronisation. As there are no Busy/Idle bits and the frame is divisible by eight it is not critical to the hardware operation. Data Transmitter The Modem transmitter is considerably simpler than the receiver. It contains a data register for writing data 8 bits at a time and Manchester encoding circuitry. It also contains timing and interrupt circuitry. Data to be transmitted is written one byte at a time to TXD[7:0]. This data is then transmitted on the next IRQ-TX interrupt, if the output is enabled. Bit 7 (most significant) is transmitted first. The Data Transmitter generates the IRQ-TX interrupts at the correct rate for the chosen system (800 µs for AMPS or 1000 µsforTACS)regardlessofwhetherthetransmitter is enabled or not. The Transmitter encodes the data into Manchester format before transmission. This is achieved by Description Function ENMOD = 1 MDMSLP = 0 MDMRESN = 1 LF1_2 = 0 RXDINV = Setup to system NOMPLL = 0 SQLEV[3:0] = Set as required A_TN = Set as Required Disable all Modem Interrupts VC_CCN = 0 SYNDET = 0 ENWS = 1 Enable IRQ-WS interrupt Ensure the IRQ-WS interrupts are occurring in the correct time window. It is up to the system designer to determine the exact criteria. When this occurs set: ENWS = 0 within 1ms SYNDET = 1 Enable IRQ-RX interrupt within 800 µs. Read and Squelch on interrupt Ensure IRQ-WS occurs in correct time window. The data registers should contain AAH, B8H & 12H at the end of a frame. 1 2 2 5 6 7 8 Set up Initialise Acquire Verify Lock Read Data Check Table 79 Data sychronisation and acquisition sequence |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |