| поискавой системы для электроныых деталей |
|
VT8235 датащи(PDF) 84 Page - VIA Technologies, Inc. |
|
|
|||||||||||||||||||||||||||||
VT8235 датащи(HTML) 84 Page - VIA Technologies, Inc. |
|
84 / 145 page ![]() VT8235 V-Link South Bridge Revision 1.22 October 24, 2002 -78- Device 17 Function 0 Power Management Registers UrpuytvrÃDp XrÃ8rp Offset 98 – GP2 / GP3 Timer Control .............................RW 7 GP3 Timer Start On setting this bit to 1, the GP3 timer loads the value defined by Rx5A and starts counting down. The GP3 timer is reloaded at the occurrence of certain events enabled in the GP Timer Reload Enable Register (Power Management I/O Space Offset 38h). If no such event occurs and the GP3 timer counts down to zero, then the GP3 Timer Timeout Status bit is set to one (bit-13 of the Global Status register at Power Management Register I/O Space Offset 28h). Additionally, if the GP3 Timer Timeout Enable bit is set (bit-13 of the Global Enable register at Power Management Register I/O Space Offset 2Ah), then an SMI is generated. 6 GP3 Timer Automatic Reload 0 GP3 Timer stops at 0 ............................ default 1 Reload GP3 timer automatically after counting down to 0 5-4 GP3 Timer Tick Select 00 Disable .................................................. default 01 1/16 second 10 1 second 11 1 minute 3 GP2 Timer Start On setting this bit to 1, the GP2 timer loads the value defined by Rx59 and starts counting down. The GP2 timer is reloaded at the occurrence of certain events enabled in the GP Timer Reload Enable Register (Power Management I/O Space Offset 38h). If no such event occurs and the GP2 timer counts down to zero, then the GP2 Timer Timeout Status bit is set to one (bit-12 of the Global Status register at Power Management Register I/O Space Offset 28h). Additionally, if the GP2 Timer Timeout Enable bit is set (bit-12 of the Global Enable register at Power Management Register I/O Space Offset 2Ah), then an SMI is generated. 2 GP2 Timer Automatic Reload 0 GP2 Timer stops at 0 ............................ default 1 Reload GP2 timer automatically after counting down to 0 1-0 GP2 Timer Tick Select 00 Disable .................................................. default 01 1/16 second 10 1 second 11 1 minute Offset 99 – GP2 Timer...................................................... RW 7 Write: GP2 Timer Load Value ...............default = 0 Read: GP2 Timer Current Count Offset 9A – GP3 Timer..................................................... RW 7 Write: GP3 Timer Load Value ...............default = 0 Read: GP3 Timer Current Count Offset C3-C0 – Power Management Capability.............. RO 31-16 Power Management Capability .always reads 0002h 15-8 Next Pointer ....................................always reads 00h 7-0 Capability ID ..................................always reads 01h Offset C7-C4 – Power Mgmt Capability CSR................ RW 31-24 Power Management Data ...............always reads 00h 23-16 PM CSR P2P Support Extensions .always reads 00h 15-0 PM Control / Status (D0/D3 Only) ..default = 0000h |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |