| поискавой системы для электроныых деталей |
|
COP888EB датащи(PDF) 40 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
COP888EB датащи(HTML) 40 Page - National Semiconductor (TI) |
|
40 / 75 page ![]() Interrupts (Continued) ample, if the Software Trap routine is located at 0310 Hex, then the vector location 0yFE and -0yFF should contain the data 03 and 10 Hex, respectively. When a Software Trap in- terrupt occurs and the VIS instruction is executed, the pro- gram jumps to the address specified in the vector table. The interrupt sources in the vector table are listed in order of rank, from highest to lowest priority. If two or more enabled and pending interrupts are detected at the same time, the one with the highest priority is serviced first. Upon return from the interrupt service routine, the next highest-level pending interrupt is serviced. If the VIS instruction is executed, but no interrupts are en- abled and pending, the lowest-priority interrupt vector is used, and a jump is made to the corresponding address in the vector table. This is an unusual occurrence, and may be the result of an error. It can legitimately result from a change in the enable bits or pending flags prior to the execution of the VIS instruction, such as executing a single cycle instruc- tion which clears an enable flag at the same time that the pending flag is set. It can also result, however, from inadvert- ent execution of the VIS command outside of the context of an interrupt. The default VIS interrupt vector can be useful for applica- tions in which time critical interrupts can occur during the servicing of another interrupt. Rather than restoring the pro- gram context (A, B, X, etc.) and executing the RETI instruc- tion, an interrupt service routine can be terminated by return- ing to the VIS instruction. In this case, interrupts will be serviced in turn until no further interrupts are pending and the default VIS routine is started. After testing the GIE bit to ensure that execution is not erroneous, the routine should restore the program context and execute the RETI to return to the interrupted program. This technique can save up to fifty instruction cycles (t c), or more, (50 µs at 10 MHz oscillator) of latency for pending in- terrupts with a penalty of fewer than ten instruction cycles if no further interrupts are pending. To ensure reliable operation, the user should always use the VIS instruction to determine the source of an interrupt. Al- though it is possible to poll the pending bits to detect the source of an interrupt, this practice is not recommended. The use of polling allows the standard arbitration ranking to be al- tered, but the reliability of the interrupt system is compro- mised. The polling routine must individually test the enable and pending bits of each maskable interrupt. If a Software Trap interrupt should occur, it will be serviced last, even though it should have the highest priority. Under certain con- ditions, a Software Trap could be triggered but not serviced, resulting in an inadvertent “locking out” of all maskable inter- rupts by the Software Trap pending flag. Problems such as this can be avoided by using VIS instruction. TABLE 10. Interrupt Vector Table Arbitration Rank Interrupt Source Description Vector Address 1 Software Trap INTR Instruction 0yFE–0yFF 2 reserved NMI 0yFC–0yFD 3 CAN Receive RBF, RFV set 0yFA–0yFB 4 CAN Error TERR, RERR set 0yF8–0yF9 (transmit/receive) 5 CAN Transmit TBE set 0yF6–0yF7 6 Pin G0 Edge External 0yF4–0yF5 7 MICROWIRE/PLUS BUSY Goes Low 0yF2–0yF3 SPI Interface SRBF or STBE set 8 Timer T0 Idle Timer Underflow 0yF0–0yF1 9 UART receive buffer full 0yEE–0yEF 10 UART transmit buffer empty 0yEC–0yED 11 Timer T2 T2A/Underflow 0yEA–0yEB 12 Timer T2 T2B 0yE8–0yE9 13 Timer T1 T1A/Underflow 0yE6–0yE7 14 Timer T1 T1B 0yE4–0yE5 15 Port L, Port M; Port L Edge or 0yE2–0yE3 MIWU Port M Edge 16 Default VIS Interrupt VIS Interrupt 0yE0–0yE1 Note 27: y is a variable which represents the VIS block. VIS and the vector table must be located in the same 256-byte block except if VIS is located at the last ad- dress of a block. In this case, the table must be in the next block. www.national.com 40 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |