27 / 75 page ![]() Functional Block Description of the CAN Interface (Continued) an interrupt by setting the Transmit Interrupt Enable bit (TIE). When servicing the interrupt the user has to make sure that TBE gets cleared by executing a WRITE instruction on the TxD2 register, otherwise a new interrupt will be generated immediately after return from the interrupt service routine. The TBE bit is read only. It is set to 1 upon reset. TBE is also set upon completion of transmission of a valid message. TXPND Transmission Pending This bit is set as soon as the Transmit Start/Stop (TXSS) bit is set by the user. It will stay set until the frame was success- fully transmitted, until the transmission was successfully can- celed by writing zero to the Transmission Start/Stop bit (TXSS), or the device enters the bus-off state. Resetting the TXSS bit will only cancel a transmission if the transmission of a frame hasn’t been started yet (bus idle) or if arbitration has been lost (receiving). If the device has already started transmission (won arbitration) the TXPND flag will stay set until the transmission is completed, even if the user’s soft- ware has requested cancellation of the message. If an error occurs during transmission, a requested cancellation may occur prior to the begining of retransmission. RRTR Received Remote Transmission Request This bit is set when the remote transmission request (RTR) bit in a received frame was set. It is automatically reset through a read of the RXD1 register. To detect RRTR the user can either poll this flag or enable the receive interrupt (the reception of a remote transmission request will also cause an interrupt if the receive interrupt is enabled). If the receive interrupt is enabled, the user should check the RRTR flag in the service routine in order to distin- guish between a RRTR interrupt and a RBF interrupt. It is the responsibility of the user to clear this bit by reading the RXD1 register, before the next frame is received. ROLD Received Overload Frame This bit is automatically set when an Overload Frame was received on the bus. It is automatically reset through a read of the Receive/Transmit Status register. It is the responsibil- ity of the user to clear this bit by reading the Receive/ Transmit Status register, before the next frame is received. RORN Receiver Overrun This bit is automatically set on an overrun of the receive data register, i.e., if the user’s program does not maintain the RxDn registers when receiving a frame. It it automatically re- set through a read of the Receive/Transmit Status register. It is the responsibility of the user to clear this bit by reading the Receive/Transmit Status register before the next frame is re- ceived. RFV Received Frame Valid This bit is set if the received frame is valid, i.e., after the pen- ultimate bit of the End of Frame is received. It is automati- cally reset through a read of the Receive/Transmit Status register. It is the responsibility of the user to clear this bit by reading the receive/transmit status register (RTSTAT), be- fore the next frame is received. RFV will cause a Receive In- terrupt if enabled by RIE. The user should be careful to read the last data byte (RxD1) of odd length messages (1, 3, 5 or 7 data bytes) on receipt of RFV. RFV is the only indication that the last byte of the message has been received. RCV Receive Mode This bit is set after the data length code of a message that passes the device’s acceptance filter has been received. It is automatically reset after the CRC-delimiter of the same frame has been received. It indicates to the user’s software that arbitration is lost and that data is coming in for that node. RBF Receive Buffer Full This bit is set if the second Rx data byte was received. It is reset automatically, after the RxD1-Register has been read by the software. RBF can be programmed to generate an in- terrupt by setting the Receive Interrupt Enable bit (RIE). When servicing the interrupt, the user has to make sure that RBF gets cleared by executing a LD instruction from the RxD1 register, otherwise a new interrupt will be generated immediately after return from the interrupt service routine. The RBF bit is read only. TRANSMIT ERROR COUNTER (TEC) (Address X’00AD) TEC7 TEC6 TEC5 TEC4 TEC3 TEC2 TEC1 TEC0 Bit 7 Bit 0 This register is read/write. For test purposes and to identify the node status, the trans- mit error counter, an 8-bit error counter, is mapped into the data memory. If the lower seven bits of the counter overflow, i.e., TEC7 is set, the device is error passive. CAUTION To prevent interference with the CAN fault confinement, the user must not write to the REC/TEC registers. Both counters are automatically updated following the CAN specification. RECEIVE ERROR COUNTER (REC) (00AE) ROVL REC6 REC5 REC4 REC3 REC2 REC1 REC0 Bit 7 Bit 0 This register is read/write. ROVL receive error counter overflow For test purposes and to identify the node status the receive error counter, a 7-bit error counter, is mapped into the data memory. If the counter overflows the ROVL bit is set to indi- cate that the device is error passive and won’t transmit any active error frames. If ROVL is set then the counter is frozen. MESSAGE IDENTIFICATION a. Transmitted Message The user can select all 11 Transmit Identifier Bits to transmit any message whigh fulfills the CAN2.0, part B spec without an extended identifier (see note below). Fully automatic re- transmission is supported for messages no longer than 2 bytes. b. Received Messages The lower four bits of the Receive Identifier are don’t care, i.e., the controller will receive all messages that fit in that win- dow (16 messages). The upper 7 bits can be defined by the user in the Receive Identifier High Register to mask out groups of messages. If the RIAF bit is set, all messages will be received. Note: The CAN interface tolerates the extended CAN frame format of 29 identifier bits and gives an acknowledgment. If an error occurs the re- ceive error counter will be increased, and decreased if the frame is valid. BUS SYNCHRONIZATION DURING OPERATION Resetting the TxEN1 and TxEN0 bits in Bus Control Register will disable the output drivers and do a resynchronization to the bus. All other CAN related registers and flags will be un- affected. www.national.com 27 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |