| поискавой системы для электроныых деталей |
|
AD9789BBCZ датащи(PDF) 61 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9789BBCZ датащи(HTML) 61 Page - Analog Devices |
|
61 / 76 page ![]() AD9789 Rev. A | Page 61 of 76 INTERRUPT REQUESTS Operating the Mu Controller in Manual Mode The following interrupt (IRQ) requests can be used for additional information and verification of the status of various functional blocks: In manual mode, the user must sweep through all the mu delay values and record the phase value at each value of MUDLY as shown in Figure 118. Every time that the MUDLY value is stepped, the MUSAMP bit must be toggled from low to high to read the corresponding phase for the specified mu delay line value. It is not possible to keep read high and continuously read back the phase value. As with auto mode, the optimal ac perfor- mance occurs at a positive slope and a phase of 14; therefore, when the curve is complete, choose the MUDLY value that corresponds to this condition and write that value to the MUDLY[8:0] bits (Register 0x39[7] and Register 0x3A). • PARERR—triggered when one or more parity errors occurs on the data bus • PARMSET—triggered when PARMNEW is set and internally registered • PARMCLR—triggered when PARMNEW is cleared and internally registered • LOCKACQ—triggered when the mu controller is locked to the user-defined phase Calculating Mu Delay Line Step Size • LOCKLOST—triggered when the mu controller loses lock (if the LOCKACQ bit was previously set) Stepping through all of the mu delay line values and plotting mu phase vs. mu delay not only allows the user to find the optimal mu delay value, but can also allow the user to determine the mu delay line step size. To calculate the step size, take one full cycle of the mu phase curve and divide the period of the DAC clock by this delta. From Figure 118, the two transition points are approximately 56 and 270, providing a delta of approx- imately 214 steps. Therefore, the mu delay line step size would be approximately 2 ps/step, as shown in the following equation: • SATERR—triggered when one or more saturation errors occurs Each IRQ is enabled using the enable bits in the interrupt enable register, Register 0x03. The status of the IRQ can be measured in one of the following ways: via the SPI bits found in the interrupt status/clear register (Register 0x04) or using the IRQ pin (Pin P2). If the pin is used to determine that an interrupt has occurred, it is necessary to check Register 0x04 to determine which bit caused the interrupt because the pin indicates only that an interrupt has occurred. To clear an IRQ, it is necessary to write a 1 to the bit in Register 0x04 that corresponds to the interrupt. ps 95 . 1 214 GHz 4 . 2 1 = ⎟ ⎟ ⎠ ⎞ ⎜ ⎜ ⎝ ⎛ If the mu controller is enabled, this value allows the user to calculate (in picoseconds) how much drift is in their system with respect to the DAC clock period over temperature. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |