| поискавой системы для электроныых деталей |
|
AD9789BBCZ датащи(PDF) 59 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9789BBCZ датащи(HTML) 59 Page - Analog Devices |
|
59 / 76 page ![]() AD9789 Rev. A | Page 59 of 76 Operating the Mu Controller in Auto Mode The mu controller is enabled via Register 0x33[0]. Enabling the controller sets in motion the phase search mode. Before enabling the controller, it is important to turn on both the phase comparator boost (Register 0x3E[5]) and the mu control duty cycle correction circuitry (Register 0x30[7]). Both of these functions allow for more robust operation of the mu controller over the entire operating speed of the part. The three modes of operation for the mu con- troller are specified by the MODE[1:0] bits in Register 0x33[5:4] as follows: • Search and track (00) (optimal setting) • Track only (01) • Search only (10) The search algorithm begins at a specified mu delay value set using the MUDLY[8:0] bits, where the LSB is located in Register 0x39[7] and the MSBs are located in Register 0x3A[7:0]. Even though there are nine bits of resolution for this delay line value, the maximum allowable mu delay is 431 (decimal). The optimal point to begin the search is in the middle of the delay line, or approximately 216. The initial search algorithm works by sweep- ing through different mu delay values until the desired phase is measured; this phase is specified using the MUPHZ[4:0] bits in Register 0x39[4:0], with the maximum allowable phase being 16. If values larger than 16 are loaded, the controller will not lock. When the desired phase is measured, the slope of the phase measurement is calculated and compared to the desired slope, which is specified by the SLOPE bit in Register 0x33[6]. For optimal ac performance, the best setting for the search is a positive slope and a phase value of 14. If the phase and slope match the configured values, the search algorithm is finished. The SEARCH_TOL bit (Register 0x2F[7]) can be used to specify the accuracy of the search as follows: • Not exact (0): can find a phase within two values of the desired phase • Exact (1): finds the exact phase specified (optimal setting) Figure 118 shows a typical plot of mu phase vs. mu delay line value at 2.4 GSPS. Starting at the selected mu delay value, the search direction can be specified via the SEARCH_DIR[1:0] bits in Register 0x39[6:5]. The three possible choices for the search are as follows: • Down only (00) • Up only (01) • Alternating up and down (10) (optimal setting) If the search direction is alternating, the search proceeds in both directions until a programmable guard band is reached in one of the directions, specified by the GUARDBAND[4:0] bits in Register 0x2F[4:0]. When the guard band is reached, the search continues only in the opposite direction. If the desired phase is not found before the guard band is reached in the second direc- tion, the search reverts to the alternating mode and continues looking within the guard band. The search fails if the mu delay reaches the endpoints. If the controller does not find the desired phase during the search, the TRACK_ERR bit (Register 0x2F[5]) determines the corrective action as follows: • Continue (0): continues to search (optimal setting) • Reset (1) 18 16 14 12 10 8 6 4 2 0 0 40 80 120 160 200 240 280 320 360 400 440 MU DELAY GUARD BAND GUARD BAND SEARCH STARTING LOCATION DESIRED PHASE AND SLOPE Figure 118. Typical Mu Phase Characteristics @ 2.4 GSPS To determine whether the search is on the correct slope, the controller measures the slope by first incrementing and then decrementing the mu delay value until any of the following events happens: • The phase changes by 2. • The phase is equal to 16 (the maximum value). • The phase is equal to 0 (the minimum value). • The mu delay is 431 (the maximum value). • The mu delay is 0 (the minimum value). After incrementing and then decrementing the mu delay value, the values of the measured phases are compared to determine whether the slope matches the desired slope. To consider the slope valid, the positive direction phase and the negative direction phase must be on opposite sides of the desired phase. Examples of valid and invalid phase choices are shown in Figure 119 and Figure 120. DESIRED DESIRED POSITIVE SLOPE NEGATIVE SLOPE 10 11 12 13 14 15 9 8 7 6 5 4 Figure 119. Valid Positive and Negative Slope Phase Examples |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |