| поискавой системы для электроныых деталей |
|
PCA5010 датащи(PDF) 32 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCA5010 датащи(HTML) 32 Page - NXP Semiconductors |
|
32 / 112 page ![]() 1998 Nov 02 32 Philips Semiconductors Product specification Pager baseband controller PCA5010 6.11.2 CLOCK CORRECTION CONTROL REGISTER (CCON) The CCON special function register is used to control the clock correction by software. Table 20 Clock Correction Control Register (CCON, SFR address FCH) Table 21 Description of the CCON bits 6.11.3 CLOCK CORRECTION INTERVAL REGISTERS (CC0 AND CC1) The CC0 and CC1 special function registers (together with CCON.3 and CCON.4) are used to define the interval between subsequent clock correction actions. Table 22 Clock Correction Interval Register (CC0, SFR address FDH) Table 23 Clock Correction Interval Register (CC1, SFR address FEH) 76543210 ENB PLUS TEST CIV17 CIV16 − BYPASS SET BIT SYMBOL FUNCTION CCON.7 ENB Enable clock correction. If ENB = 1 has been set, then correction is enabled and will stay enabled even when the DC/DC converter is shut down and restarted. CCON.6 PLUS ± Sign for value. If PLUS = 1 then clock pulses are inserted, or else deleted. CCON.5 TEST Test signal, must always be logic 0 in normal mode. It is used during test to bypass the first 9 FFs in the timing generator divider chain. If TEST = 1 the clock rate of the signals 9600 Hz and 256 Hz is doubled and the frequency on 16 Hz and 4 Hz is multiplied by 300. CCON.4 CIV17 bit 17 of interval value, is used as extension of CC0 and CC1 CCON.3 CIV16 bit 16 of interval value, is used as extension of CC0 and CC1 CCON.2 − unused. CCON.1 BYPASS Test signal, must always be logic 0 in normal mode. It is used during test to generate 76.8 kHz on all outputs of the timing generator (4 Hz, 16 Hz, 256 Hz and 9600 Hz). CCON.0 SET A load signal to the interval register. After a logic 0 to logic 1 transition of this bit the value of ENB, PLUS, TEST, BYPASS and CIV are copied into the local latches with the next 76.8 kHz clock pulse. A duration of one MOV instruction is long enough for the set operation to complete. The SFR values must remain stable for at least one oscillator period because the actual transfer happens synchronized with the local clock (see Figs 16 and 18). 76543210 CIV7 CIV6 CIV5 CIV4 CIV3 CIV2 CIV1 CIV0 76543210 CIV15 CIV14 CIV13 CIV12 CIV11 CIV10 CIV9 CIV8 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |